GB
6
2. INSTALLATION OF LOAD LIMITER HF 31/1/A2
DANGER
: Product must be installed by a qualified technician.
2.1. Parts list of load limiter and its environment
2.2. Installing the load limiter on the wire rope
a) Position the compression pin (14) in accordance with the force in the wire rope.
IMPORTANT
Before applying a load and if
no factory presetting has been
requested, make sure the
adjustment screws are un
-
screwed to the maximum.
Failure to do so will result in risk
of destruction of micro-switches
by crushing.
If the wire rope diameter does
not correspond to the load
range, the load information will
be the decisive information.
1 Connecting cable
2 Cable gland
3 Cotter pin
4 Zinc-plated washer
5 Nameplate
6 Adjustment screw and
locknut
7 Adjustment screw and
locknut
8 Protective rubber piece
9 Deformation cell
10 Lower guide
11 Fixed half-clamp
12 Mounting screw
13 Mobile half-clamp
14 Compression pin
15 Upper guide
16 Pull wire rope
17 Winch
18 Pulley block
19 Hook
20 Sensor
21 Fixed point
POSITION 0
Pour un câble de 5 à 8 mm et
des charges comprises entre
200 kg et 900 daN.
POSITION 1
Pour un câble de 9 à 13 mm et
des charges comprises entre
200 kg et 1850 daN.
POSITION 2
Pour un câble de 14 à 16 mm et
des charges comprises entre
200 kg et 3200 daN.
0 POSITION
For a 5 to 6 mm wire rope
and loads of between
200 and 900 kg.
1 POSITION
For a 9 to 13 mm wire rope
and loads of between
200 and 1 850 kg.
2 POSITION
For a 14 to 16 mm wire
rope and loads of between
200 and 3 200 kg.