TRACO POWER TSP-BCM24 Скачать руководство пользователя страница 1

 

Tel:  +41 43 311 4511
Fax: +41 43 311 4545

[email protected] 
www.tracopower.com

 

Date:  19 October 2006 
Issue: 1.3

 

Page
Seite

1

 

 

Jenatschstrasse 1
CH-8002 Zürich 

 

 
 
 

 
 
 
 
 
 

 
 
 
 

 

 

 

 

 

 

 

 

  Operating Instructions  

B

ATTERY 

C

ONTROLLER 

M

ODULE 

TSP-BCM24

 

Содержание TSP-BCM24

Страница 1: ...41 43 311 4511 Fax 41 43 311 4545 sales traco ch www tracopower com Date 19 October 2006 Issue 1 3 Page Seite 1 Jenatschstrasse 1 CH 8002 Z rich Operating Instructions BATTERY CONTROLLER MODULE TSP BC...

Страница 2: ...rticular can they provide for every possible example of installation operation or maintenance Further information is available from your local distributor office or from the TSP industrial power suppl...

Страница 3: ...e of 80mm 3 15in is required and on each side of the TSP BCM24 a minimum space of 50mm 1 97in is required which allows air convection The air temperature measured 10mm 0 39in below the device must not...

Страница 4: ...e Bat In and Bat In connections Make sure that the battery lines are dimensioned according to the maximum output current see 2 2 1 1 or are separately protected The wires on the secondary side should...

Страница 5: ...e sensing optional The TSP BCM24 device is designed to operate with temperature compensation required for proper operation of the battery The temperature is detected using an external NTC sensor 10k c...

Страница 6: ...pin 7 and pin 8 connect via a switch Contact closed Device off Signal Relay Contacts 30Vdc 1A Remote link cable 0 5m 1 cable included with TSP BCM24 module Case protection in accordance to IEC 529 IP2...

Страница 7: ...com Date 19 October 2006 Issue 1 3 Page Seite 7 Jenatschstrasse 1 CH 8002 Z rich 6 1 Block diagram TSP BCM24 6 2 Connection of TSP BCM24 Fig 2 1 Fig 1 1 Remote Link J3 1 J3 2 J1 2 J1 1 J2 3 J2 4 J2 1...

Страница 8: ...3 J4 J5 J6 Pin 1 Vin DC In GND S 15 sec test AC OK Signal TSP 360 124 Factory setting Pin 2 Vin DC In GND S Com AC OK Relay contact TSP 180 124 Pin 3 Bat in Vout 10 min test Bat OK Signal TSP 090 124...

Страница 9: ...teries Two 12V batteries are connected in series and assembled inot a stainless steel enclosure with integrated connector and connection cable 8 Technical Specifications 8 1 Input Specifications Order...

Страница 10: ...311 4511 Fax 41 43 311 4545 sales traco ch www tracopower com Date 19 October 2006 Issue 1 3 Page Seite 10 Jenatschstrasse 1 CH 8002 Z rich 8 3 Dimensions 8 3 1 TSP BAT 034 8 3 2 TSP BAT 072 8 3 2 TS...

Отзывы: