Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: Dec. 30
th
, 2014 / Rev.:1
INSTALLATION
INFORMATION
TMPS 03Series AC/DC POWER MODULE
Order Code
Output Power max.
Output
TMPS 03-103
3 Watts
3.3Vdc / 900mA
TMPS 03-105
3 Watts
5Vdc / 600mA
TMPS 03-109
3 Watts
9Vdc / 333mA
TMPS 03-112
3 Watts
12Vdc / 250mA
TMPS 03-115
3 Watts
15Vdc / 200mA
TMPS 03-124
3 Watts
24Vdc / 125mA
Input Voltage Range:
85-264VAC / 60-50Hz
Input Current:
65mA typ. at Vin = 115VAC
40mA typ. at Vin = 230VAC
Operation Temperature Range:
-25
℃
~+70
℃
max.
Terminal for
Wiring:
PCB mounting with solder pin’s.
Output Power Derating:
+60
℃ to
+70
℃
Î
0.15W/
℃
Internal Fuse:
T1A 250VAC Min
Case Material: Plastic Resin + Fiberglas
UL 94V-0 flammability rating
Safety Instructions:
¾
Before installation read these instructions carefully and
completely. This installation instruction cannot claim for every
possible example of installation, operation or maintenance.
Further information’s are obtainable from your local distributor
office or from the product data sheet which can be downloaded
from the Internet at http://www.tracopower.com/
¾
The power supplies are constructed in accordance with the
safety requirements of cUL/UL/IEC/EN60950-1 and
IEC/EN60335-1. They fulfil the requirements of the Low
Voltage Directive (LVD) and carries the CE-mark. UL and cUL
are approved in accordance to UL60950-1, and TUV is
approved in accordance to IEC/EN60335-1.
¾
Before an installation, maintenance or modification work
ensure that the main switch is switched off and prevented from
being switched on again. In case of non-observance touching
at any alive components or improper dealing with this power
supply can result in death, severe personal injury or substantial
property damage. The successful and safe operation is
dependent of proper storage, handling, installation and
operation.
¾
Compliance with the relevant national regulations (in the USA,
Europe and the other countries) must be observed and
ensured. Before operation is started the following conditions
must be ensured:
Connection to mains supply in compliance with national
regulations (VDE0100 and EN50178).
By use of stranded wires, all strands must be fastened in the
terminal blocks.
Power supply and mains cables must be sufficiently fused.
All output wires must be rated for the power supply output
current and must be connected with the correct polarity.
Sufficient cooling must be ensured
Keep away from fire and water
¾
Never work on the power supply if power is supplied!
Risk
of electric arcs and electrical shock which can cause death,
severe personal injury of substantial property damage.
¾
Warning:
Hazardous voltages and components storing a very
substantial amount of energy are present in this power supply
during normal operating conditions. However, these are
inaccessible. Improper handling may result in an electric shock
or serious burns!
¾
For the assembly information of chosen AC/DC Power Module,
see the AC/DC Power Module specification and rating label for
details:
Make sure the dimensions of location for assembly
complying with category or specification datasheet.
Do not expose the AC/DC Power Module to excessive heat,
moisture, dust, or corrosive gases.
The overall dimensions of AC/DC Power Module shall be
assembled according to the ventilation designs of end-use
product.
Do not open the power supply until at least 5 minutes after
it has been disconnected from the mains on all poles.
◆
Avertissement:
Ce bloc d’alimentation contient une grande
tension et des composants puissants pendant l’utilisation
normale. Une mauvaise manipulation peut causer un choc
électrique ou des brûlures graves !
◆
Pour assembler ce module d’alimentation CA/CC, veuillez
vous référer aux spécifications et la plaque signalétique du
module CA/CC :
◆
La dimension de l’endroit de l’assemblage doit correspondre
à la catégorie ou aux spécifications.
◆
Il ne faut pas exposer ce module d’alimentation CA/CC à la
chaleur, à l’humidité, à la poussière ou aux gaz corrosifs.
◆
La dimension générale du module CA/CC doit respecter le
système de ventilation du produit fini.
Avant d’ouvrir le bloc d’alimentation, attendre au moins 5
minutes après la déconnexion de tous les pôles