background image

TU501-x 

 

 

 

Short Guide TU501-x v4.2, May 2019, ©Trackunit 2019

 

 

15 

 

Approvals and Certifications 

 

 

FCC/IC part 15.19 

Notice 

 

 

This device complies with Part 15 of the FCC Rules and with Industry 

Canada license-exempt RSS standard(s). Operation is subject to the 

following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

 

 
IC RSS-GEN 

Notice 
 

 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables 

aux appareils radio exempts de licence. L'exploitation est autorisée aux 

deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, 

et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique 

subi, même si le brouillage est susceptible d'en compromettre le 

fonctionnement. 

 

 
FCC part 15.21 

Notice 
 

 

Changes or modifications made to this equipment not expressly approved 

by Trackunit may void the FCC authorization to operate this equipment. 

 

 

FCC/IC 

Radiofrequency 

radiation exposure 

Information 
 

 

This equipment complies with FCC/IC radiation exposure limits set forth for 

an uncontrolled environment. This equipment may be installed and 

operated with minimum distance of 5 cm between the radiator and your 

body. 

This transmitter must not be co-located or operating in conjunction with any 

other antenna or transmitter. 

 

 
Environmental 

compliance 
 

 

IEC 61373 - EN/IEC 60068-2-1:2007 - Cold 

IEC 61373 - EN/IEC 60068-2-2:2006 - Dry Heat 

EN 50125-1 - EN/IEC 60068-2-27:2010 - Shock 

SAE J1455 - EN/IEC 60068-2-31:2008 - Drop 

EN 50125-1, SAE J1455 - EN/IEC 60068-2-64:2008 - Random vibration 

IEC 61373 - EN/IEC 60068-2-78:2001 - Damp heat steady state 

IEC 61373 - (IEC 60529+A1+A2) CSV:2013 - Degrees of protection (IP 

code): IP67 

 

NOTE A: The TU501 is not to be mounted in areas with presence of motor 

oil, gasoline, diesel fuel, hydraulic fluid, brake fluid, transmission fluid, 

glycol and water mixture, etc. 

 

NOTE B: The housing is not designed to withstand high pressure cleaning. 

Only use the TU501 when mounted inside the designated Trackunit 

protection cap (7402.9551 Trackunit Raw hardware shield can be ordered 

at Trackunit) in mounting areas where high pressure cleaning is common 

procedure. 

 

Содержание TU501 Series

Страница 1: ...NOTE Former model ID was ME501 x 2G 3G Model ID changed in 2017 to TU501 x 2G 3G Short guide TU501 x Version 4 2 May 2019...

Страница 2: ...allation example 5 Functionality check LED on the unit 6 Installation check and update using Verify my Trackunit 7 Input filtering INFILT 8 CAN bus termination resistor 9 Troubleshooting 10 Product sp...

Страница 3: ...is located on the unit The mobile number and unit serial number are located on the box label It can be peeled off and saved for later use Do not perform installation inside a building Install the uni...

Страница 4: ...1 Digital input 3 Optional input1 Digital input 4 Can be used for INFILT function Optional input2 Digital output 1 Can be used to control a relay3 4 Additional input for TU501 2 1 Wire input M8 connec...

Страница 5: ...TU501 x Short Guide TU501 x v4 2 May 2019 Trackunit 2019 5 Installation example...

Страница 6: ...is OK and GPS has valid satellite position No light in LED No power supply Constant red light and no green light in LED Power supply is OK but NO mobile network GPS has NO satellite position Red flas...

Страница 7: ...GPS and mobile signal Mobile number Power supply voltage Internal battery voltage Status of inputs 1 4 on off Click Find again to refresh status Step 4 Basic configuration options Enter a device name...

Страница 8: ...rs To avoid this situation the digital input 4 pink wire should be connected to the chassis ground on the machine The infilt function should be activated via Verify my Trackunit Activation of input fi...

Страница 9: ...ller or if the TU501 4 is to be installed as a stub on a CAN bus with multiple CAN devices already attached The 120 ohm termination resister is a permanently installed resistor so make sure to use and...

Страница 10: ...g operating hours when machine is off Possibly due to the main breaker being on the negative wire ground wire from the machine battery When off the inputs may register a voltage level and start counti...

Страница 11: ...pply voltage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM receiver active 10 mA 7 mA avg at 12V 24V Consumption during charging an empty battery 225 mA 115 mA...

Страница 12: ...is either machinery or battery powered Storage 40 C to 70 C Shorter battery lifetime must be expected when storage and operation occur at extreme temperatures Mechanical specifications Length 106 mm...

Страница 13: ...C rules and with RSS GEN RSS 132 RSS 133 RSS 210 and ICES 003 of the Industry Canada requirements Environmental The TU501 products comply with the environmental conditions for rolling stock and transp...

Страница 14: ...dard b Supply voltage 12V 48V Max 30A i FKS blade fuse Max 80V 3A ATO style used with Littelfuse FH2 fuse holder recommended Machinery The TU501 products comply with the essential requirements of the...

Страница 15: ...C IC Radiofrequency radiation exposure Information This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment may be installed and operated...

Страница 16: ...unit ME501 9 New model ID TU501 9 Japan ID n R 003 150064 T D150059003 This device is granted pursuant to the Japanese Radio Law This device should not be modified otherwise the granted designation nu...