Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
08/31/2017
TR - ECE - BA - DGB - 0105 - 03
Page 89 of 103
6.1.4 S-0-0600.0.12 Encoder error code
Error codes of the measuring system:
Bit
Value
Description
Comments
15-0
Detailed failure code
0000.0000.0000.0110 Error when reading
C0270
0000.0000.0000.0101 Invalid settings for controller cycle time
C0223
0000.0000.0000.0100 Initialization velocity too high
C0221
0000.0000.0000.0100 Error when initializing position
C0220
0000.0000.0000.0011 Parameter conversion error
C0203
0000.0000.0000.0010 Parameter limit error
C0202
0000.0000.0000.0001 Parameter invalid
C0201
Parameter-Format, Encoder error code
name
Encoder error code
attribute length (octet)
2
data type and display format
binary
function
parameter
positions after decimal point
0
write protection
always
conversion factor
1
scaling / resolution of LSB
1
unit
n/a
minimum value
n/a
maximum value
n/a
scope of parameter
local