Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
08/31/2017
TR - ECE - BA - DGB - 0105 - 03
Page 87 of 103
6.1.2 S-0-0600.0.01 Encoder status
Output of the measuring system status:
Bit Value Description
Comments
15-14
Ready to operate
00
not ready
transmitted data are invalid
01
reserved
-
10
reserved
-
11
ready
transmitted data are valid
13
Encoder error
0
no error
no error detected
1
error
internal error detected
12
Encoder warning
0
no warning
no warning detected
1
warning
Warning detected, output data are still valid
11-6
reserved
-
5
Position Status
0
position not valid
Initialization failed
1
position valid
Initialization correct, data valid
4
Reference marker
latched
not supported
0
not latched
-
1
latched
-
3
Direction polarity
Definition: view onto the shaft
0
not inverted
Position increasing clockwise (default)
1
inverted
Position decreasing clockwise
2
Cyclic marker
evaluation
not supported
0
not active
-
1
active
-
1
reserved
-
0
Encoder-Type
0
rotational
Rotary measuring system (default)
1
linear
Linear measuring system