Printed in the Federal Republic of Germany
TR-Electronic GmbH 2005, All Rights Reserved
11/06/2018
TR - ECE - BA - DGB - 0045 - 06
Page 101 of 132
Operating parameter Code SSI-Interface
Description see page 118
DDLM_Set_Prm
unsigned8
Byte
21
Bit
7
6
5
4
3
2
1
0
Data
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Gray code
(default)
0
0
0
0
0
0
0
0
Binary code
0
0
0
0
0
0
0
1
Shifted Gray code
0
0
0
0
0
0
1
0
Operating parameter Code PROFIBUS-Interface
Description see page 118
DDLM_Set_Prm
unsigned8
Byte
22
Bit
7
6
5
4
3
2
1
0
Data
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Gray code
0
0
0
0
0
0
0
0
Binary code
(default)
0
0
0
0
0
0
0
1
Shifted Gray code
0
0
0
0
0
0
1
0
Operating parameter Preset 1 / Preset 2
Description see page 118
DDLM_Set_Prm
unsigned32
Byte
23
24
25
26
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
0
Preset 1
DDLM_Set_Prm
unsigned32
Byte
27
28
29
30
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
1
Preset 2