Printed in the Federal Republic of Germany
TR-Electronic GmbH 2005, All Rights Reserved
11/06/2018
TR - ECE - BA - DGB - 0045 - 06
Page 99 of 132
Overview of operating parameters
see note on page 90
Parameter
Data type
Byte
Not supported!
Format
Description
Count direction
bit
9
Short Diagnostics
bit
9
Commissioning diagnostics
bit
9
Teach-In function
unsigned8
10
X
Total measuring range
unsigned32 11 – 14
Revolutions numerator
unsigned32 15 – 18
Revolutions denominator
unsigned16 19 – 20
Code SSI-Interface
unsigned8
21
QEH-80
Code PROFIBUS-Interface
unsigned8
22
Preset 1
unsigned32 23 – 26
QEH-80
Preset 2
unsigned32 27 – 30
QEH-80
Lower limit switch
unsigned32 31 – 34
Upper limit switch
unsigned32 35 – 38
Data bits SSI-Interface
unsigned8
39
QEH-80
Bit coded operating parameters
DDLM_Set_Prm
Byte
9
Bit
7 – 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Count direction
ascending position values
for clockwise rotation
X
ascending position
values counter-
clockwise rotation
1
Short Diagnostics
yes
no
X
2
Commissioning
diagnostics
switched off
X
switched on