Parameterization via TRWinProg
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 66 of 67
TR-ECE-BA-DGB-0141 v03
03/19/2021
5.7.4 Set K0
Risk of injury and damage to property by an actual value jump when the
Set K0 adjustment function is performed!
The Set K0 function should only be performed when the measuring system
is at rest, otherwise the resulting actual value jump must be permitted in
the program and application!
The Set K0 function only can be executed if the input signal is present statically for
>50 ms at the input. After approx. 0.5 s the zero pulse signal at the output is set. If the
Set K0 function input is not used, he should be disabled to suppress interference.
Selection
Description
Default
In use
Set K0 function active
Not in use
Set K0 function inactive
X
5.7.5 Signal level
Selection
Description
Default
Supply voltage
Output driver: Push-Pull; Level = Supply voltage
X
TTL
Output driver: RS422; Level = 5 VDC
With a supply voltage of US = 5 V and the selection of
supply voltage
, the current
consumption is significantly increased!
This behavior must be taken into account in the case of evaluation units which also
supply the measuring system.