9.3.3 Object 0x2F0E: DS402M.MPX
Object code
ARRAY
Description
Configuration of the following error
Subindex 0: Number of entries
Data type
UNSIGNED8
Attribute
ro
Default
0
Min
0
Max
4
PDO mapping
-
Description
Number of following entries
Subindex 1: Following Error Options
Data type
INTEGER16
Attribute
rw
Default
-
Min
-2
15
Max
+2
15
-1
PDO mapping
no
Description
1 -> A following error triggers a non-fatal fault, that reacts
according to the option code 0x605E
2 -> A following error immediately turns off the drive.
3 -> A following error triggers a quick stop, that reacts
according to the option code 0x605A.
Hint: If this option code is 5 or higher, which means staying in
quick stop, this state can be left without turning off the motor
by toggling the control word bit 0x80 "Clear Fault" once or
twice.
0 or any other value -> A following error only sets the status
word bit and sends its emergency.
Also see chapter “Stop conditions: Priorities, Behavior” on
page 124.
Subindex 2: Q24 Profile Restart Window /rev.
Data type
UNSIGNED32
Attribute
rw
Default
-
Min
0
Max
+2
32
-1
PDO mapping
no
Description
If the following error window is switched off, this limit for the
following error is used in revolutions for restart of speed and
positioning ramps. Q24 means 24 bits after the comma,
therefore max. 256 revolutions.
Function: Avoids sudden and uncontrolled movements of the
drive after enabling of a blocked drive. Dependent on the
adjusted mode of operation (0x6060 = 1 or 3), the target
speed or target position is reached considering the velocity
and acceleration limits.
Also see chapter “Stop conditions: Priorities, Behavior” on
page 124.