9.2.3 Object 0x1003: Pre-defined Error Field
Object name
Pre-defined Error Field
Object code
ARRAY
Description
This parameter stores the last 8 occurring errors as maximum. The "newest" error
is stored in subindex 1. As the subindex increases, the error entries become older.
The error entries are of the type UNSIGNED32. The higher-value part (bits 16-31)
is intended for device-specific information and is not used by the encoTRive. The
meaning of bits 0-15 can be taken from Table 37 on page 150.
Subindex 0: Number of error entries
Data type
UNSIGNED8
Attribute
rw
Default
0
Min
0
Max
8
PDO mapping
-
Description
Contains the number of stored errors. Writing the value 0 in
this element means that the complete error list is deleted.
Other values are not permitted and result in an abort
message with the error code 0x0609 0030.
Subindex 1: Error no. 1
Data type
UNSIGNED32
Attribute
ro
Default
0
Min
0
Max
-
PDO mapping
-
Description
Last occurring error
Subindex 2: Error no. 2
Data type
UNSIGNED32
Attribute
ro
Default
0
Min
0
Max
-
PDO mapping
-
Description
Older error message (position 2)
...
Subindex 8: Error no. 8
Data type
UNSIGNED32
Attribute
ro
Default
0
Min
0
Max
-
PDO mapping
-
Description
Oldest error message (position 8)