Parameterization and configuration
TR-Electronic GmbH 2003, All Rights Reserved
Printed in the Federal Republic of Germany
Page 20 of 22
TR - ELA - TI - GB - 0040 - 06
02/13/2017
7.3 Parameters / Range of values
7.3.1 Direction
Instance Service Value
Description
Default
1
r/w
= 0
increasing position values to the rod end
X
0
decreasing position values to the rod end
7.3.2 Output Code
Instance Service Value
Description
Default
2
r/w
= 0
Binary code
X
0
Gray code
7.3.3 Total Number of Steps
Instance 3, r/w
Defines the
Total number of steps
of the measuring system related to the measuring
length and corresponds to the resolution.
lower limit
15 steps
upper limit
16 777 215 steps (24 bit)
default
15
Standard value:
The given measuring length on the rating plate multiplied with 100 corresponding to
the resolution of 0.01 mm.
Measuring length in steps =
Measuring length
Resolution in mm