7.1.1 Standard Mode
Index
0x2000
Object type
VAR
Name
Mode
Data type
UNSIGNED8
Category
Optional
Value range
Bit 0 = 0: Standard
Access
rw
Default value
0
PDO mapping
no
The
Standard
Mode corresponds to the normal mode of operation of the measuring
system. The physical zero point of the measuring system is at point 1, the upper limit
of range is at point 2.
Definition:
● Setting a Preset value refers to the respective magnet
● Counting method of the magnets: Outgoing from point 1, increasing
Figure 11: Mode "Standard"