Parameterization
TR-Electronic GmbH 2020, All Rights Reserved
Printed in the Federal Republic of Germany
Page 66 of 88
TR - ELE - BA - DGB - 0030 - 01
06/15/2020
Index 0x004D: Error Output Value
7.2.6
The parameter
Error Output Value
determines which position value should be transmitted in
case of an error. The data value is output, if the measuring system can output no more measurement.
This is given e.g., if a beam interruption is present.
Index
Subindex
Name
Length
Type
Access
0x004D
0
Error Output Value
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
Position = 0
The position is set to '0'
X
0x01
Position = -1
All 32 bits are set to '1' (0xFFFFFFFF or -1)
0x02
Last valid value
Output of the last valid position
7.3 Position - Parameter
Index 0x0046: Count Direction
7.3.1
The parameter
Count Direction
defines the counting direction for the position value.
Index
Subindex
Name
Length
Type
Access
0x0046
0
Count Direction
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
Positive
With increasing distance to the measuring system:
values increasing
X
0x01
Negative
With increasing distance to the measuring system:
values decreasing