Printed in the Federal Republic of Germany
TR-Electronic GmbH 2020, All Rights Reserved
06/15/2020
TR - ELE - BA - DGB - 0030 - 01
Page 63 of 88
7 Parameterization
Parameter data are exchanged acyclic via the ISDU and only on request of the IO-link master. The
parameter data are addressed by means of a so-called
Index
and
Subindex
. Parameterization via
the DirectParameterPage2 of the page communication channel (index 0x01, subindex 0x10…0x1F) is
not possible.
This mechanism is performed as an acknowledged service. The IO-Link master specifies in its
Request
the parameter
Index
, the access method (
Read/Write
) and if necessary the value. The
IO-Link device
performs the write or read access and answers the request with a
Response
. In the
case of an error (error code = 0x80) an error message gives information about the cause of error, see
chapter “ISDU error types” on page 85. The written parameter data are directly saved permanently
and activated.
By means of subindex 0x00 the complete index is addressed, by means of the sub-indices
0x01…0xFF the individual parameters are addressed, if these are available.
Danger of physical injury and material damage due to an actual value
jump within the process data if parameter data are written!
If parameter data are written the process data are set to "0" for about
300 ms (Process data - status =
INVALID
). In this time the process data
must not be used and the application must be in a safe condition.
7.1 Index 0x0010 - 0x0018: Identification parameters
The identification parameters contain device data that the IO-Link master uses to identify the
connected device more precisely.
These device data can be read out by means of their index and subindex = 0x00 from the device or
can be written into the device if write access is permissible.
The objects with index
0x0040 are optional and were added by the manufacturer.
Index
Object Name
Description
Value
(StringT)
Access
0x0010
Vendor Name
Vendor name
TR-Electronic GmbH
ro
0x0011
Vendor Text
Vendor text
www.tr-electronic.com
ro
0x0012
Product Name
Product name
LE-25
ro
0x0013
Product ID
Product-ID
Device specific
ro
0x0014
Product Text
Product text
Linear Encoder
ro
0x0015
Serial-Number
Serial number
Device specific
ro
0x0016
Hardware Revision
Hardware version
Device specific
ro
0x0017
Firmware Revision
Firmware version
Device specific
ro
0x0040
Order number
Part number
2600-xxxxx
ro
0x0049
Max. Resolution
Maximum resolution
1 (2500000)
ro
To describe the user specific application, function and location each object supports a text string with
a size of 32 bytes:
Index
Object Name
Value
(StringT)
Type
Access
0x0018
Application Specific Tag
‘***’
StringT32
rw
0x0019
Function Tag (UTF-8)
‘***’
StringT32
rw
0x001A
Location Tag (UTF-8)
‘***’
StringT32
rw