Parameterization and configuration
TR-Electronic GmbH 2008, All Rights Reserved
Printed in the Federal Republic of Germany
Page 96 of 109
TR - ECE - BA - DGB - 0068 - 01
06/19/2012
7.8.11 Lower limit switch / Upper limit switch
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
TR-Mode Position
X TR-Mode Po Rpm.
not supported!
not supported!
–
If the status switched on (see Teach-In function page 89) the measuring system can
inform the master via a bit whether the actual value is within the limits.
Limit switch bit = 0
actual value lower limit or actual value upper limit
Limit switch bit = 1
actual value < lower limit or actual value > upper limit
lower limit
0
upper limit
programmed total measuring length in increments
– 1,
within 16 777 216
default
Lower limit switch = 0, Upper limit switch = 4096