Parameterization via TRWinProg
TR-Electronic GmbH 2012, All Rights Reserved
Printed in the Federal Republic of Germany
Page 64 of 68
TR - ECE - BA - DGB - 0091 - 02
11/15/2012
8.3 Analog values
8.3.1 Mode Analog output
Selection
Description
Default
no Analog function
Analog interface switched off
Voltage (in mV)
Operating mode Analog Voltage
X
Current (in µA)
Operating mode Analog Current
8.3.2 Start position / End position Analog
With the parameter
Start position Analog
and
End position Analog
the
active measuring range within the programmed measuring length in steps can be
defined. The start position must be defined smaller than the end position and the end
position smaller than the programmed measuring length in steps.
Figure 8: Active measuring range, rotation = CW; counting direction = up
Legend
A
O
= Analog output quantity in Volt or Milli-Ampere
A
max
= maximum value of the analog output quantity [V, mA]
ML
= by the scaling parameters programmed measuring length in steps
Pos
= actual position of the measuring system in steps
Start-Pos.
= Initial position analog in steps, default = 0
End-Pos.
= Final position analog in steps, default = 1048575 or 16777215
Pos = ( A
O
* (End-Pos. – Start-Pos.) ) / A
max
+ Start-Pos.