![TR-Electronic CM*-36 Series Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/tr-electronic/cm-36-series/cm-36-series_user-manual_1146702087.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2016, All Rights Reserved
11/20/2018
TR - ECE - BA - DGB - 0128 - 01
Page 87 of 127
3.7 Layer setting services (LSS) and protocols
The LSS-services and protocols, documented in CiA DS-305 V3.0, are used to inquire
or to change the settings of several parameters of the data link layer and application
layer of a LSS slave by a LSS master via the CAN network.
Following parameters are supported:
-
Node-ID
-
Baud rate
-
LSS address compliant to the identity object (1018h)
Access to the LSS slave is made thereby by its LSS address, consisting of:
-
Vendor-ID
-
Product-Code
-
Revision-No. and
-
Serial-No.
The measuring system supports the following services:
Switch state services
●
Switch state selective
●
Switch state global
Configuration services
●
Configure Node-ID
●
Configure bit timing parameters
●
Activate bit timing parameters
●
Store configured parameters
Inquiry services
●
Inquire LSS address
●
Inquire Node-ID
Identification services
●
LSS identify remote slave
●
LSS identify slave
●
LSS identify non-configured remote slave
●
LSS identify non-configured slave