Operating parameter Lower limit switch / Upper limit switch
Description see page 123
DDLM_Set_Prm
unsigned32
Byte
31
32
33
34
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
0
Lower limit switch
DDLM_Set_Prm
unsigned32
Byte
35
36
37
38
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
4096
Upper limit switch
Operating parameter Data bits SSI-Interface
Description see page 123
DDLM_Set_Prm
unsigned8
Byte
39
Bit
7 – 0
Data
2
7
– 2
0
Default (dec.)
24
Operating parameter Velocity)
Description see page 123
DDLM_Set_Prm
unsigned8
Byte
40
Bit
7 – 0
Data
2
7
– 2
0
Default (dec.)
1