Parameterization
TR-Electronic GmbH 2008, All Rights Reserved
Printed in the Federal Republic of Germany
Page 116 of 155
TR - ECE - BA - DGB - 0073 - 07
06/27/2017
7.4.3.1 Attribute 0x03, Position 32
Position 32
(Instance 1) returns the position value of the measuring system as 32
bit value.
Position value 32 Bit, CEx-65
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x04
0x24
0x01
0x30
0x03
Logical Type
= Class
Class #4
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #3
7.4.3.2 Attribute 0x03, Position 64
Position 64
(Instance 101) returns the position value of the measuring system as
64 bit value.
Position value 64 Bit, COx-65
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
2
39
up to 2
32
2
47
up to 2
40
2
55
up to 2
48
2
63
up to 2
56
Connection path,
Packed EPATH
with 8 bit class
0x20
0x04
0x24
0x65
0x30
0x03
Logical Type
= Class
Class #4
Logical Type
= Instance
Instance #101
Logical Type
=Attr.-ID
Attr.-ID #3
7.4.4
Connection Point
s
Connection Points
within the
Assembly Object
are identical to Instances. For
example, Connection Point 4 of the
Assembly Object
is the same as Instance 4.