Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
09/23/2014
TR - ECE - BA - DGB - 0102 - 03
Page 143 of 171
8.4.3.31 Attribute 105, TR-Parameter in use (scaling)
TR-Parameter in use
sets which scaling attributes are in use.
BOOL
Access
Value
Description
Default
Set / Get
= 0
Standard EthernNet/IP scaling attributes in use
X
= 1
Manufacturer specific TR scaling attributes in use
Standard EthernNet/IP scaling parameters:
-
Attribute 16, Measuring Units per Span
-
Attribute 17, Total Measuring Range in Measuring Units
Manufacturer specific TR scaling parameters
:
-
Attribute 101, Total Measuring Range
-
Attribute 102/103, Revolution Numerator/Denominator
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x69
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #105
This attribute only takes effect after executing service code 0x16
save
or attribute 112
Accept Parameter
.
8.4.3.32 Attribute 106, Temperature Value
Temperature Value
contains the actual temperature of the measuring system.
The unit is defined in “Attribute 107, Temperature Value Format” it is standardly °C.
INT, read only
Temperature
Byte 0
Byte 1
2
7
up to 2
0
2
15
up to 2
8
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6A
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #106