Error Causes and Remedies
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2010, All Rights Reserved
10/07/2013
TR - ECE - BA - DGB - 0080 - 05
Page 175 of 176
12.4.1 Emergency Error Codes
Error Code (hex)
Description
00xx
Error reset or no error
10xx
General error
50xx
Device hardware
60xx
Device software
61xx
Internal software
62xx
User software
63xx
Data record
80xx
Monitoring
81xx
Communication
82xx
Protocol error
8210
PDO not processed, due to a length error
8210
PDO length exceeded
90xx
External error
A0xx
EtherCAT state machine transition error
A000
PRE-OPERATIONAL --> SAVE-OPERATIONAL transition unsuccessful
A001
SAVE-OPERATIONAL --> OPERATIONAL transition unsuccessful
FFxx
Device-specific
Table 10: Emergency Error Codes
12.4.2 Error Register
Bit
M/O
Description
0
M
General error
1
O
not supported
2
O
not supported
3
O
not supported
4
O
Communication error (overflow, error status)
5
O
Device profile-specific
6
O
reserved, always 0
7
O
Manufacturer-specific
Table 11: Structure of the error register