Manufacturer and Profile Specific Objects (CiA DS-406)
TR-Electronic GmbH 2010, All Rights Reserved
Printed in the Federal Republic of Germany
Page 164 of 176
TR - ECE - BA - DGB - 0080 - 05
10/07/2013
10.12.4 Object 6503h: Alarms
Additionally to the emergency message, object 6503h provides further alarm
messages. An alarm is set if a malfunction in the measuring system could lead to an
incorrect position value. If an alarm occurs, the according bit is set to logical high until
the alarm is cleared and the measuring system is able to provide an accurate position
value.
Index
0x6503
Description
Alarms
Data type
UNSIGNED16
Category
Mandatory
Access
ro
PDO mapping
Yes
Bit
Function
Bit = 0
Bit = 1
0
Position error
No
Yes
1
Reserved for further use
2
Reserved for further use
3
Reserved for further use
4
Reserved for further use
5
Reserved for further use
6
Reserved for further use
7
Reserved for further use
8
Reserved for further use
9
Reserved for further use
10
Reserved for further use
11
Reserved for further use
12
EE-PROM error
OK
error
13
Manufacturer specific functions
14
Manufacturer specific functions
15
Manufacturer specific functions
Position error
The bit is set, if the measuring system detects a malfunction of the system.
EE-PROM error
The measuring system detects a wrong checksum in the EE-Prom area or a write
process into the EE-Prom could not be finished successfully.