Manufacturer and Profile Specific Objects (CiA DS-406)
TR-Electronic GmbH 2010, All Rights Reserved
Printed in the Federal Republic of Germany
Page 154 of 176
TR - ECE - BA - DGB - 0080 - 05
10/07/2013
10.5 Object 2402h: K0 Condition
The object 2402h is only available with optional incremental interface. It defines the
switching time of the Incremental tracks K0 and /K0.
Index
0x2402
Description
K0 Condition
Data type
UNSIGNED16
Category
Optional
Access
rw
PDO mapping
No
Default
0
Value
Behaviour
0
K0 if K1 = high and K2 = high
1
K0 if K1 = low and K2 = high
2
K0 if K1 = high and K2 = low
3
K0 if K1 = low and K2 = low
Example:
Figure 11: Example to K0 Condition
10.6 Object 2403h: Preset K0
The object 2403h is only available with optional incremental interface. With writing of
"1" to this object, the zero pulse K0 will be set to the current measuring system
position and it is saved immediately.
Index
0x2403
Description
Preset K0
Data type
UNSIGNED16
Category
Optional
Access
rw
PDO mapping
nein
Default
0