11.1.2.2 Setting and saving IP parameters
The IP parameters can be set or saved via the
TCP/IP Interface Object
, Class code 0xF5, in
two ways:
1. A
Set_Attribute_Single
service on Attribute 5
Interface Configuration
causes
the values transferred as parameters to be set. The configuration is also permanently stored in
the FLASH if the value of Attribute 3
Configuration Control
= 0x00 during executing of
the action.
2. The current configuration is permanently saved in the FLASH if the measuring system has
received a configuration via DHCP, the current value of Attribute 3 Configuration Control =
0x02, and the Configuration Control value is set to 0x00.