1 INTRODUCTION 

Thank you for purchasing the TQC impact tester. Your impact tester has been designed to meet high 
quality standards. TQC impact testers are on the cutting edge of innovation, and are a part of a wide 
range of high quality test products. The impact tester is designed to withstand heavy use, please note 
that this is different from abuse. Therefore please read this manual carefully if necessary in conjunction 
with the used standard. 
 
Although this manual has been written with the greatest care there is always the possibility that 
subsequent changes have not been included. Please always use common sense when reading this 
document. 
 
 

1.1

 

About the TQC Impact Tester 

Impact test or rapid deformation tests are widely used to evaluate coating quality by determining its resistance to deformation, 
hereby checking elasticity and adhesion. These both values determine coatings behaviour after rapid deformation. The energy 
applied to the test panel is obtained by using the formula: Ep = m * g * h : Energy (in Nm or Joule) = mass * gravity * height.  
 
The test is performed by placing a planar panel free of distortion onto a levelled die. Depending on the required method a punch is 
either placed or dropped on the panel together with the impact weight. After impact the panel is removed and evaluated for the 
amount of deformation. Depending on the used international or national standard the method of preparation and evaluation may 
vary. 
 
 

1.2

 

Complies with standards 

Below mentioned standards are a list of the possible standards. If the required standard is not listed below please contact TQC to 
check if adoption of this standard is possible*: 
 

 

SP1880 SP1890 SP1891 SP1895 

Type of Impact 

Indirect 

Direct 

Direct 

Direct 

ISO 6272-1:2002 

 

 

 

 

ISO 6272-2:2002 

 

 

 

 

ISO 6272:1993 

 

 

 

 

ASTM D 2794:2004 

 

 

 

 

ASTM G14-04 

 

 

 

 

JIS K 5600-5-3:1989 

 

 

 

 

EN 12206-1:2004 

 

 

 

 

EN 13523-5:2001 

 

 

 

 

AAMA 2605-05 

 

 

 

 

Qualicoat 2006 

 

 

 

 

Qualisteelcoat 2008 

 

 

 

 

 

* Conformation to a required standard depends on the impact tester type. The combination of items can change to comply with 
another standard. 

MANUAL

Содержание SP1880

Страница 1: ...aviour after rapid deformation The energy applied to the test panel is obtained by using the formula Ep m g h Energy in Nm or Joule mass gravity height The test is performed by placing a planar panel...

Страница 2: ...tant that it is not only assembled the correct way but also placed on a suitable location The height is the guide tube posts limitations to where it can be placed but also the force created at impact...

Страница 3: ...P1891 SP1895 1 Guide tube 2 6 13 Base plate assembly with bubble level 3 Die 16 3 mm 3 Die 27 0 mm 4 Weight 1 kg 5 Weight Lifting Pin 7 Punch 15 9 mm 8 Punch 12 7 mm 9 Lifting pin to release punch 10...

Страница 4: ...n the sample that is the test object test sample with coating layer downwards 10 Hold the guide tube while releasing it by turning the handle 6 Move the guide tube until the weight lifter lines with 0...

Страница 5: ...er of the falling weight 4 Make sure the punch still can be lifted by pushing the red button and the falling weight can be moved freely through the guide tube 5 Set the release collar to the desired h...

Страница 6: ...ake sure the punch still can be lifted by pushing the red button and the falling weight can be moved freely through the guide tube 5 Set the release collar to the desired height by putting the slit fo...

Страница 7: ...on please follow the following guidelines Never put your hands under the tube when the weight is raised Always have a stamp in place when testing Make sure the TQC impact tester is positioned fully le...