background image

 

User's Manual  l  TQMx50UC UM 0101  l  © 2018 TQ-Group 

 

Page  1 

 

 

1.

 

ABOUT THIS MANUAL 

1.1

 

Copyright and License Expenses 

Copyright protected © 2018 by TQ-Systems GmbH. 
This User's Manual may not be copied, reproduced, translated, changed or distributed, completely or partially in electronic, 
machine readable, or in any other form without the written consent of TQ-Systems GmbH. 
The drivers and utilities for the components used as well as the BIOS are subject to copyrights of the respective manufacturers. 
The licence conditions of the respective manufacturer are to be adhered to. 
BIOS-licence expenses are paid by TQ-Systems GmbH and are included in the price. 
Licence expenses for the operating system and applications are not taken into consideration and have to be calculated / 
declared separately. 
 
 

1.2

 

Registered Trademarks 

TQ-Systems GmbH aims to adhere to copyrights of all graphics and texts used in all publications, and strives to use original  
or license-free graphics and texts. 
All brand names and trademarks mentioned in the publication, including those protected by a third party, unless specified 
otherwise in writing, are subjected to the specifications of the current copyright laws and the proprietary laws of the present 
registered proprietor without any limitation. One should conclude that brand and trademarks are rightly protected by a third 
party. 
 
 

1.3

 

Disclaimer 

TQ-Systems GmbH does not guarantee that the information in this User's Manual is up-to-date, correct, complete or of good 
quality. Nor does TQ-Systems GmbH assume guarantee for further usage of the information. Liability claims against TQ-Systems 
GmbH, referring to material or non-material related damages caused, due to usage or non-usage of the information given in the 
User's Manual, or due to usage of erroneous or incomplete information, are exempted, as long as there is no proven intentional 
or negligent fault of TQ-Systems GmbH. 
TQ-Systems GmbH explicitly reserves the rights to change or add to the contents of this User's Manual or parts of it without 
special notification. 
 
 

1.4

 

Imprint 

TQ-Systems GmbH 
Gut Delling, Mühlstraße 2 

D-82229 Seefeld 

 
Tel: 

+49 8153 9308–0 

Fax: 

+49 8153 9308–4223 

Email: 

[email protected]

 

Web: 

TQ-Group

 

 
 

1.5

 

Service and Support 

Please visit our website 

TQ-Group

 for latest product documentation, drivers, utilities and technical support. 

You can register on our website 

TQ-Group

 to have access to restricted information and automatic update services. 

For direct technical support you can contact our FAE team by email: 

TQ-Support

Our FAE team can also support you with additional information like 3D-STEP files and confidential information, which is not 
provided on our public website. 
For service/RMA, please contact our service team by email (

TQ-Service

) or your sales team at TQ-Systems GmbH. 

 

Содержание TQMx50UC

Страница 1: ...User s Manual l TQMx50UC UM 0101 l 2018 TQ Group Page i TQMx50UC User s Manual TQMx50UC UM 0101 2018 09 26...

Страница 2: ...ironmental Specification 8 3 4 System Components 8 3 4 1 Processor 8 3 4 1 1 Intel Turbo Boost Technology 9 3 4 1 2 Intel Configurable Thermal Design Power 9 3 4 2 Graphics 9 3 4 3 Chipset 9 3 4 4 Mem...

Страница 3: ...xternal Effects 24 5 SOFTWARE 25 5 1 System Resources 25 5 1 1 I2C Bus 25 5 1 2 SMBus 25 5 1 3 Memory Map 25 5 1 4 IRQ Map 25 5 2 Operating Systems 26 5 2 1 Supported Operating Systems 26 5 2 2 Driver...

Страница 4: ...port 25 Table 12 I2C address mapping COM Express SMBus port 25 Table 13 Acronyms 29 Table 14 Further Applicable Documents and Links 31 ILLUSTRATION DIRECTORY Illustration 1 Block Diagram TQMx50UC 6 Il...

Страница 5: ...at brand and trademarks are rightly protected by a third party 1 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Manual is up to date correct complete or of good qu...

Страница 6: ...is symbol represents important details or aspects for working with TQ products Command A font with fixed width is used to denote commands contents file names or menu items 1 8 Handling and ESD Tips Ge...

Страница 7: ...nts used for example CompactFlash cards are to be taken note of They contain if applicable additional information that must be taken note of for safe and reliable operation These documents are stored...

Страница 8: ...Intel Celeron 3765U 2 1 7 GHz 2 MB Cache HD Hyper Threading and Virtualization support 15 W TDP max configurable down to 9 5 10 W Memory DDR3L 1600 dual channel 4 Gbyte and 8 Gbyte memory down config...

Страница 9: ...d Temp 0 to 60 C Please visit to TQ Group TQMx50UC for a complete list of standard versions Other configurations are available on request Standard configuration features are CPU version Memory configu...

Страница 10: ...s are specified at the COM Express connector Wide input 8 5 V to 20 V maximum input ripple 100 mV VCC_5V_SBY 4 75 V to 5 25 V maximum input ripple 50 mV VCC_RTC 2 0 V to 3 3 V maximum input ripple 20...

Страница 11: ...C DC power supplies on the TQMx50UC are switched off The following table shows the power consumption with different processor configurations Table 2 TQMx50UC Power Consumption Mode Standby 5 V Wide in...

Страница 12: ...Configurable Thermal Design Power Intel cTDP Intel Enhanced Intel SpeedStep technology Up to 4 Mbyte cache Intel HD Graphics Triple independent displays Table 4 Processor Specifications Mode i7 5650U...

Страница 13: ...ive cooling solutions The cTDP can be configured in the uEFI BIOS the default setting is nominal 3 4 2 Graphics The 5th Generation Intel Core 5000U processor series includes an integrated Intel HD gra...

Страница 14: ...or GoldCap capacitor backup Temperature compensation 40 C to 85 C Time deviation 0 26 s day 3 0 ppm Time keeping voltage down to 1 5 V Please contact TQ Support for further information about the iRTC...

Страница 15: ...AID capability provides high performance RAID 0 1 5 and 10 functionality on up to 4 SATA ports of the SATA host controller Matrix RAID support is provided to allow multiple RAID levels to be combined...

Страница 16: ...ed for special functions see 3 4 8 3 5 10 High Definition Audio Interface The TQMx50UC provides a High Definition Audio HDA interface which supports two audio codecs at the COM Express connector The H...

Страница 17: ...D24 SER1_RTS 3 3 V output SER1_CTS D25 SER1_CTS 3 3 V input Note Protection circuits In Revision 2 0 of the COM Express specification the signals A98 A99 A101 and A102 have been reclaimed from the VC...

Страница 18: ...rmation The following table illustrates some LED boot messages Table 8 LED boot messages Red LED Green LED Remark ON OFF Power supply error ON ON S4 S5 state BLINKING BLINKING S3 state OFF BLINKING uE...

Страница 19: ...ntial transmit pairs O A23 SATA2_TX SATA differential transmit pairs O A24 SUS_S5 Indicates system is in Soft Off state Active low output O PD TQ flexiCFG A25 SATA2_RX SATA differential receive pairs...

Страница 20: ...pairs 3 O A80 GND FIXED Ground GND A81 LVDS_A_CK LVDS Channel A differential clock O A82 LVDS_A_CK LVDS Channel A differential clock O A83 LVDS_I2C_CK I2C clock output for LVDS display I O A84 LVDS_I...

Страница 21: ...n power supply I PU TQ flexiCFG B25 SATA3_RX SATA differential receive pairs I B26 SATA3_RX SATA differential receive pairs I B27 WDT watchdog time out O TQ flexiCFG B28 AC HDA_SDIN2 Serial TDM data i...

Страница 22: ...Channel B differential pairs 3 O B79 LVDS_BKLT_EN LVDS panel backlight enable O B80 GND FIXED Ground GND B81 LVDS_B_CK LVDS Channel B differential clock O B82 LVDS_B_CK LVDS Channel B differential cl...

Страница 23: ...irs 4 O N A C27 RSVD18 Reserved NC C28 RSVD18 Reserved NC C29 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C30 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C31 GND FIXED Ground GND...

Страница 24: ...Express differential receive pairs I N A C79 PEG_RX8 PCI Express differential receive pairs I N A C80 GND FIXED Ground GND C81 PEG_RX9 PCI Express differential receive pairs I N A C82 PEG_RX9 PCI Exp...

Страница 25: ...ort 1 Clear To Send I PU TQ flexiCFG D26 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D27 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D28 RSVD18 Reserved NC D29 DDI1_PAIR1 DDI1 DP HDMI DV...

Страница 26: ...xpress differential transmit pairs O N A D79 PEG_TX8 PCI Express differential transmit pairs O N A D80 GND FIXED Ground GND D81 PEG_TX9 PCI Express differential transmit pairs O N A D82 PEG_TX9 PCI Ex...

Страница 27: ...mensions The dimensions of the TQMx50UC are 95 95 mm2 0 2 mm The following illustration shows the Three View Drawing of the TQMx50UC Illustration 2 Three view drawing TQMx50UC The following illustrati...

Страница 28: ...he heat spreader acts as a thermal coupling device to the TQMx50UC The heat spreader is thermally coupled to the processor and provides optimal heat transfer from the TQMx50UC to the heat spreader The...

Страница 29: ...m Management Bus SMBus The following table shows the I2C address mapping for the COM Express SMBus port Table 12 I2C address mapping COM Express SMBus port 8 bit Address Function Remark 0xA0 0xA4 SPD...

Страница 30: ...hipset Components in the Device Manager can be downloaded at this Intel page https downloadcenter intel com download 20775 Intel Chipset Device Software INF Update Utility The Intel Driver Update Util...

Страница 31: ...ctrostatic discharge should be arranged directly at the inputs of a system As these measures always have to be implemented on the carrier board no special preventive measures were done on the TQMx50UC...

Страница 32: ...QMx50UC 7 6 Packaging By environmentally friendly processes production equipment and products we contribute to the protection of our environment To be able to reuse the TQMx50UC it is produced in such...

Страница 33: ...cally Erasable Programmable Read Only Memory EMC Electromagnetic Compatibility eSATA external Serial ATA ESD Electrostatic Discharge FAE Field Application Engineer FIFO First In First Out flexiCFG Fle...

Страница 34: ...er RAM Random Access Memory RMA Return Merchandise Authorization RoHS Restriction of the use of certain Hazardous Substances RSVD Reserved RTC Real Time Clock SATA Serial ATA SCU System Control Unit S...

Страница 35: ...com download 20775 Intel Chipset Device Software INF Update Utility https downloadcenter intel com download 24345 Intel Driver Update Utility Intel 3 5th Generation Intel Core 5000U series Broadwell U...

Страница 36: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l TQ Group...

Отзывы: