background image

 

User's Manual  l  TQMx50UC UM 0101  l  © 2018 TQ-Group 

 

Page  29 

 

8.

 

APPENDIX 

8.1

 

Acronyms and Definitions 

The following acronyms and abbreviations are used in this document. 
 

Table 13: 

Acronyms 

Acronym 

Meaning 

ATA 

AT Attachment 

BIOS 

Basic Input/Output System 

CAN 

Controller Area Network 

CODEC 

Code/Decode 

COM 

Computer-On-Module 

CPU 

Central Processing Unit 

CSM 

Compatibility Support Module 

cTDP 

Configurable Thermal Design Power 

DC 

Direct Current 

DDC 

Display Data Channel 

DDI 

Digital Display Interface 

DDR3L 

DDR3 Low Voltage 

DMA 

Direct Memory Access 

DP 

DisplayPort 

DVI 

Digital Visual Interface 

ECC 

Error-Correcting Code 

eDP 

embedded DisplayPort 

EEPROM 

Electrically Erasable Programmable Read-Only Memory 

EMC 

Electromagnetic Compatibility 

eSATA 

external Serial ATA 

ESD 

Electrostatic Discharge 

FAE 

Field Application Engineer 

FIFO 

First In First Out 

flexiCFG 

Flexible Configuration 

FPGA 

Field Programmable Gate-Array 

FR-4 

Flame Retardant 4 

GND 

Ground 

GPIO 

General Purpose Input/Output 

HD 

High Definition 

HDA 

High Definition Audio 

HDMI 

High Definition Multimedia Interface 

HSP 

Heat Spreader 

Input 

I PD 

Input with internal Pull-Down resistor 

I PU 

Input with internal Pull-Up resistor 

I/O 

Input/Output 

I2C 

Inter-Integrated Circuit 

IEEE

®

 

Institute of Electrical and Electronics Engineers 

IoT 

Internet of Things 

IP 

Ingress Protection 

IRQ 

Interrupt Request 

iRTC 

Industrial Real Time Clock 

JTAG

®

 

Joint Test Action Group 

LED 

Light Emitting Diode 

LP 

Low-Profile 

LPC 

Low Pin Count 

LVDS 

Low Voltage Differential Signal 

 

Содержание TQMx50UC

Страница 1: ...User s Manual l TQMx50UC UM 0101 l 2018 TQ Group Page i TQMx50UC User s Manual TQMx50UC UM 0101 2018 09 26...

Страница 2: ...ironmental Specification 8 3 4 System Components 8 3 4 1 Processor 8 3 4 1 1 Intel Turbo Boost Technology 9 3 4 1 2 Intel Configurable Thermal Design Power 9 3 4 2 Graphics 9 3 4 3 Chipset 9 3 4 4 Mem...

Страница 3: ...xternal Effects 24 5 SOFTWARE 25 5 1 System Resources 25 5 1 1 I2C Bus 25 5 1 2 SMBus 25 5 1 3 Memory Map 25 5 1 4 IRQ Map 25 5 2 Operating Systems 26 5 2 1 Supported Operating Systems 26 5 2 2 Driver...

Страница 4: ...port 25 Table 12 I2C address mapping COM Express SMBus port 25 Table 13 Acronyms 29 Table 14 Further Applicable Documents and Links 31 ILLUSTRATION DIRECTORY Illustration 1 Block Diagram TQMx50UC 6 Il...

Страница 5: ...at brand and trademarks are rightly protected by a third party 1 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Manual is up to date correct complete or of good qu...

Страница 6: ...is symbol represents important details or aspects for working with TQ products Command A font with fixed width is used to denote commands contents file names or menu items 1 8 Handling and ESD Tips Ge...

Страница 7: ...nts used for example CompactFlash cards are to be taken note of They contain if applicable additional information that must be taken note of for safe and reliable operation These documents are stored...

Страница 8: ...Intel Celeron 3765U 2 1 7 GHz 2 MB Cache HD Hyper Threading and Virtualization support 15 W TDP max configurable down to 9 5 10 W Memory DDR3L 1600 dual channel 4 Gbyte and 8 Gbyte memory down config...

Страница 9: ...d Temp 0 to 60 C Please visit to TQ Group TQMx50UC for a complete list of standard versions Other configurations are available on request Standard configuration features are CPU version Memory configu...

Страница 10: ...s are specified at the COM Express connector Wide input 8 5 V to 20 V maximum input ripple 100 mV VCC_5V_SBY 4 75 V to 5 25 V maximum input ripple 50 mV VCC_RTC 2 0 V to 3 3 V maximum input ripple 20...

Страница 11: ...C DC power supplies on the TQMx50UC are switched off The following table shows the power consumption with different processor configurations Table 2 TQMx50UC Power Consumption Mode Standby 5 V Wide in...

Страница 12: ...Configurable Thermal Design Power Intel cTDP Intel Enhanced Intel SpeedStep technology Up to 4 Mbyte cache Intel HD Graphics Triple independent displays Table 4 Processor Specifications Mode i7 5650U...

Страница 13: ...ive cooling solutions The cTDP can be configured in the uEFI BIOS the default setting is nominal 3 4 2 Graphics The 5th Generation Intel Core 5000U processor series includes an integrated Intel HD gra...

Страница 14: ...or GoldCap capacitor backup Temperature compensation 40 C to 85 C Time deviation 0 26 s day 3 0 ppm Time keeping voltage down to 1 5 V Please contact TQ Support for further information about the iRTC...

Страница 15: ...AID capability provides high performance RAID 0 1 5 and 10 functionality on up to 4 SATA ports of the SATA host controller Matrix RAID support is provided to allow multiple RAID levels to be combined...

Страница 16: ...ed for special functions see 3 4 8 3 5 10 High Definition Audio Interface The TQMx50UC provides a High Definition Audio HDA interface which supports two audio codecs at the COM Express connector The H...

Страница 17: ...D24 SER1_RTS 3 3 V output SER1_CTS D25 SER1_CTS 3 3 V input Note Protection circuits In Revision 2 0 of the COM Express specification the signals A98 A99 A101 and A102 have been reclaimed from the VC...

Страница 18: ...rmation The following table illustrates some LED boot messages Table 8 LED boot messages Red LED Green LED Remark ON OFF Power supply error ON ON S4 S5 state BLINKING BLINKING S3 state OFF BLINKING uE...

Страница 19: ...ntial transmit pairs O A23 SATA2_TX SATA differential transmit pairs O A24 SUS_S5 Indicates system is in Soft Off state Active low output O PD TQ flexiCFG A25 SATA2_RX SATA differential receive pairs...

Страница 20: ...pairs 3 O A80 GND FIXED Ground GND A81 LVDS_A_CK LVDS Channel A differential clock O A82 LVDS_A_CK LVDS Channel A differential clock O A83 LVDS_I2C_CK I2C clock output for LVDS display I O A84 LVDS_I...

Страница 21: ...n power supply I PU TQ flexiCFG B25 SATA3_RX SATA differential receive pairs I B26 SATA3_RX SATA differential receive pairs I B27 WDT watchdog time out O TQ flexiCFG B28 AC HDA_SDIN2 Serial TDM data i...

Страница 22: ...Channel B differential pairs 3 O B79 LVDS_BKLT_EN LVDS panel backlight enable O B80 GND FIXED Ground GND B81 LVDS_B_CK LVDS Channel B differential clock O B82 LVDS_B_CK LVDS Channel B differential cl...

Страница 23: ...irs 4 O N A C27 RSVD18 Reserved NC C28 RSVD18 Reserved NC C29 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C30 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C31 GND FIXED Ground GND...

Страница 24: ...Express differential receive pairs I N A C79 PEG_RX8 PCI Express differential receive pairs I N A C80 GND FIXED Ground GND C81 PEG_RX9 PCI Express differential receive pairs I N A C82 PEG_RX9 PCI Exp...

Страница 25: ...ort 1 Clear To Send I PU TQ flexiCFG D26 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D27 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D28 RSVD18 Reserved NC D29 DDI1_PAIR1 DDI1 DP HDMI DV...

Страница 26: ...xpress differential transmit pairs O N A D79 PEG_TX8 PCI Express differential transmit pairs O N A D80 GND FIXED Ground GND D81 PEG_TX9 PCI Express differential transmit pairs O N A D82 PEG_TX9 PCI Ex...

Страница 27: ...mensions The dimensions of the TQMx50UC are 95 95 mm2 0 2 mm The following illustration shows the Three View Drawing of the TQMx50UC Illustration 2 Three view drawing TQMx50UC The following illustrati...

Страница 28: ...he heat spreader acts as a thermal coupling device to the TQMx50UC The heat spreader is thermally coupled to the processor and provides optimal heat transfer from the TQMx50UC to the heat spreader The...

Страница 29: ...m Management Bus SMBus The following table shows the I2C address mapping for the COM Express SMBus port Table 12 I2C address mapping COM Express SMBus port 8 bit Address Function Remark 0xA0 0xA4 SPD...

Страница 30: ...hipset Components in the Device Manager can be downloaded at this Intel page https downloadcenter intel com download 20775 Intel Chipset Device Software INF Update Utility The Intel Driver Update Util...

Страница 31: ...ctrostatic discharge should be arranged directly at the inputs of a system As these measures always have to be implemented on the carrier board no special preventive measures were done on the TQMx50UC...

Страница 32: ...QMx50UC 7 6 Packaging By environmentally friendly processes production equipment and products we contribute to the protection of our environment To be able to reuse the TQMx50UC it is produced in such...

Страница 33: ...cally Erasable Programmable Read Only Memory EMC Electromagnetic Compatibility eSATA external Serial ATA ESD Electrostatic Discharge FAE Field Application Engineer FIFO First In First Out flexiCFG Fle...

Страница 34: ...er RAM Random Access Memory RMA Return Merchandise Authorization RoHS Restriction of the use of certain Hazardous Substances RSVD Reserved RTC Real Time Clock SATA Serial ATA SCU System Control Unit S...

Страница 35: ...com download 20775 Intel Chipset Device Software INF Update Utility https downloadcenter intel com download 24345 Intel Driver Update Utility Intel 3 5th Generation Intel Core 5000U series Broadwell U...

Страница 36: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l TQ Group...

Отзывы: