TPP Pipettor Turbo-Fix
Operating instructions
155923_V13
Страница 1: ...TPP Pipettor Turbo Fix Operating instructions 155923_V13 ...
Страница 2: ...EACH 1907 2006 Capacity Labelling of Portable Secondary Batteries 1103 2010 Ecodesign Power supplies 278 2009 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 1 2010 Electrical equipment for measurement control and laboratory use EMC requirements EN 61326 1 2013 Safety requirements for electrical equipment for measurement control...
Страница 3: ... 7 5 Maintenance 10 6 Technical data 11 7 Spare parts 12 Imprint 2018 TPP Techno Plastic Products AG Supplier Customer service Please contact your local TPP Techno Plastic Products AG representative see www tpp ch or contact info tpp ch TPP Techno Plastic Products AG CH 8219 Trasadingen Switzerland T 41 52 687 01 87 F 41 52 687 01 77 info tpp ch www tpp ch ...
Страница 4: ...ettor Turbo Fix to UV light can cause discolouration and or yellowing of the plastic housing However this will not affect the performance of the device in any way 6 Old Li ion batteries may cause a safety risk We recommend to replace the battery after 3 years of use Also replace the battery if the charging intervals are unusually short or if the charging takes much longer than usual 4 hours or mor...
Страница 5: ...phobic sterile filter 0 45 µm spare Quick Start Guide 2 2 Overview of TPP Pipettor Turbo Fix 1 Aspiration button 2 Dispensing button 3 Thumb wheel to set maximum speed 4 Battery charge indicator 5 Socket for mains adapter cable 6 Handle 7 Nose piece 7 Nose piece Stabifix 7a O ring 7b Nose piece housing upper part 7c Filter rubber 7d Hydrophobic filter 7e Pipette mount 7f Nose piece housing lower p...
Страница 6: ...ng of the wall mount The wall mount serves to park TPP Pipettor Turbo Fix To mount the wall mount remove the protective foil from the adhesive tape at the back of the holder Hold it with the sign up facing upwards and press it to the desired place Make sure that the surface onto which the wall mount is mounted is smooth clean and grease free Wait 24 hours before using the wall mount for the first ...
Страница 7: ...faster for large pipettes To empty the pipette by gravity force press the dispensing button only slightly in order to avoid reaching the trigger point where the pump starts running Gravity dispensing is used for to deliver TD pipettes that are not of the blow out type blow out pipettes have two thin rings or a frosted band around the neck TPP Pipettor Turbo Fix is featured with a TURBO mode Plug t...
Страница 8: ...er Reduced aspiration efficiency or no liquid aspiration The filter 7d is wet or dirty Replace filter The nose piece 7 is not tight Tighten the nose piece or replace defective parts The battery is discharged battery charge indicator flashes red Charge the battery The battery is missing Insert the battery or connect the instrument to the mains adapter The battery is defective Replace the battery Th...
Страница 9: ...ery type is inserted Use only original Li ion battery 94756 Wrong mains adapter is used Use only original mains adapter see chapter 6 1 Battery operation not possible The battery is wrongly inserted Insert correctly note polarity and Wrong battery type is inserted Use only original Li ion battery 94756 The battery is missing Insert the battery Problem Probable cause Remedy ...
Страница 10: ...he housing of the TPP Pipettor Turbo Fix have been in contact with biohazardous material it must be decontaminated in accordance to good laboratory practice Do not spray directly on the instrument but use a lint free cloth lightly soaked with a disinfectant and wipe dry directly after decontamination Never use acetone or other solvents Follow the instructions provided by the disinfectant manufactu...
Страница 11: ... and the diluted chemical It is recommended to test the compatibility of relevant components to a specific chemical prior to extensive use TPP Techno Plastic Products AG does not warrant that the information in the table is accurate or complete and that any material is suitable for any purpose Pipetting speed max 13 5 ml s with a 50 ml serological pipette Battery Type rechargeable Li ion min 500 m...
Страница 12: ... C A C C Internal parts e g pump FPM A A A A A C C A A C NBR A B B A A A A A C C CR A A A A A A A A B A Metal C C A A B C A C A A Spare part Part No Mains adapter for Turbo Fix 100 240 VAC 50 60 Hz EU version type C plug 2 pole 94760 US JP version type A plug 2 pole 94761 UK version type G Commonwealth plug 3 pole 94762 Nose piece Stabifix 7 complete set with filter 0 45 µm unsterile 94750 Wall mo...