TPM
207-D533-NN User Manual
46
6.4
Save Parameters (1010h)
Index Sub-
Index
Name/Description
Units
Range
Data
Type
Acc
-ess
Default
value
OP
Mode
Save to
EEPROM
1010h Store parameters
00h
Highest sub-index
supported
–
–
U8
ro
1
OP
No
01h
Save all parameters
(0x00000000~0x
FFFFFFFF)
U32
rw
0x0000000
0
OP
No
Store parameters. This object is used to write (back up) the objects data into Flash Memory.
When user writes
65766173h
(“Save”) into 1010h:01, system will back up the whole target objects with retain
function into Flash Memory.
6.5
Restore Default Parameters (1011h)
Index Sub-
Index
Name/Description
Units Range
Data
Type
Acc
-ess
Default
value
OP
Mode
Save to
EEPROM
1011h Restore default parameters
00h
Highest sub-index
supported
–
–
U8
ro
1
01h
Restore default parameters
(0x00000000~0x
FFFFFFFF)
U32
rw
0x00000000
OP
No
Restore the default parameters from Flash Memory. This object is used to restore the objects to default values from
Flash Memory.
When user writes
64616F6Ch
(“load”) into 1010h:01, system will start to restore the whole target objects with
retain function from Flash Memory.