background image

Preamble

rISk claSS

Colour

Class

Risk

White WHI, Green 525 nm, Red 630 nm

0

none

UV 405 nm, Blue 470 nm, IR 850 nm

1

low

UV 365 nm

2

moderate

UV 385 nm

3

high

In all cases, TPL Vision recommends 
the use of the protection glasses 
that are listed in its catalog.

For more information about photo-
biological risks, do not hesitate to 
contact us.

USer gUIde

BewaRe to the infrared light, invisible to the eyes.
To know if the light is on, please refer to the LED indicators.

The EN-62471 norm about lighting fluxes enables the classification of led lightings in 4 distinct groups, according 
to their hazardousness degree. Please find below an indicative table, recapitulating the classes of risk for our 
standard products.

This Technical User Guide contains warnings and guidance for correct and safe operation of the product. 
These instructions must be followed at all times. TPL Vision will not be held responsible for problems caused 
by using the product contrary to these instructions and the Warranty will be deemed invalid.

TPL Vision can provide guidance notes about the nominal distance to minimize eye risks.

UnPackIng

Products are packed in our factory, using suitable materials for a safe transport through the usual means of trans-
portation, in France and internationally. However, a damaged package must be reported to the carrier on delivery. 
Hand-written reservations must be indicated on the delivery order. Moreover, please send a letter or an email to 
TPL Vision as soon as possible (up to 24 hours after the delivery). If the transportation damage has not been stipu-
lated on the delivery order and reported to TPL Vision in time, the package will not be taken back nor exchanged. 
To open the package, do not use any cutting blade to avoid damaging the product(s). Please use the delivered 
accessories, if needed (do not use any other products or equivalents to replace the delivered accessories).

Содержание BLBAR+

Страница 1: ...lowed at all times TPL Vision will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid TPL Vision can provide guidance notes about the nominal distance to minimize eye risks unpacking Products are packed in our factory using suitable materials for a safe transport through the usual means of trans portation in Franc...

Страница 2: ...er LED indicator Set at equal distance n Length Lg 600 mm 2 M4 nuts n 600 mm Lg 1250 mm 3 M4 nuts Nuts M4 supplied Screws M4 not supplied During the set up the light has to be switched off and unplugged Please use the delivered nuts and insert them in the groove located in the back of the light The light will be better fixed if you spread the attachment points as indicated on the scheme above You ...

Страница 3: ...le 24V signal power M12 4 male points T coding M12 5 male points M12 5 female points M12 4 male points T coding M12 5 male points M12 5 female points 24V Use an extension cable male female M12 M12 5 x 0 342 Front view Top view M12 5 female Points M12 5 Male Points M12 4 Male points T Coding ...

Страница 4: ...brown 24V 24V 3 GND GND blue The M12 male connector 5 points is compliant with the M12 female connector 4 points In that case the dimming option is not available Voltage drop Dimensions 125 250 375 500 625 750 875 1000 1125 1250 Max voltage drop in the bar V 0 01 0 03 0 06 0 12 0 18 0 26 0 35 0 46 0 58 0 72 Power supply cable 4x1 5 max length for acceptable voltage drop m 150 150 150 150 138 112 9...

Страница 5: ...rom 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Strobe Mode STROBE INPUT 2 ms 2 ms 15 µs 15 µs 15 µs 15 µs LIGHT 30 100 Triggering input 2 ms Triggering input 2 ms 1 ms Strobe mode LED are supplied in Overdrive Continuous mode after 2ms in Overdrive LED are supplied at a safe level for use in continuous mode D max t max f max CW 100 CW N A Strobe 5 2 ms 750 Hz D Du...

Страница 6: ... supply 125 250 375 500 625 750 875 1000 1125 1250 Power needed in Strobe W 48 96 144 192 240 288 336 384 432 480 Power needed in Continuous Working W 11 1 22 2 33 3 44 4 55 5 66 6 77 7 88 8 99 9 111 Min functioning Voltage 20V in the light input Normal functioning Voltage 24V in the light input 10 Max functioning Voltage 30V in the light input Dimming 0 10V 30 50 70 100 0 2 4 6 8 10 VOLTS Dimming...

Страница 7: ...cannot be implemented supply the operators with glasses class 4 available for sale at TPL Vision or with a dedicated protective mask that will stop the lighting radiation Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond the recommendations of the manufa...

Страница 8: ...se School Road Charing Kent TN27 0JW UK Tel 44 0 1738 310 392 www tpl vision com Features and presentations liable to changes without notice Documentation valid from June 2017 until further notice Ref UG 010103 C1 2020 09 edition ...