background image

ELECTRIC FORCED AIR HEATER

 

MODEL TSH20J

 

THIS HEATER IS DESIGNED FOR MOUNTING IN THE KICKSPACE OF KITCHEN AND BATHROOM CABINETS.  IT MAY ALSO BE 

MOUNTED WITH THE GRILLE IN A VERTICAL POSITION INSTEAD OF THE HORIZONTAL POSITION AS SHOWN.  THE HEATER 
MAY  BE  USED  WITH  A  WALL  LINE  VOLTAGE  THERMOSTAT  OR  WITH  BUILT-IN  THERMOSTAT  ACCESSORY  KIT  MODEL(S) 
TSH1TX (SINGLE POLE) OR TSH2TX (DOUBLE POLE). 

OPERATING INSTRUCTIONS 

THE THERMOSTAT CONTROL CAN BE EITHER THE WALL TYPE OR BUILT INTO THE UNIT ON THE LEFT SIDE OF THE GRILLE. 

IT SHOULD BE SET TO THE POSITION THAT GIVES THE DESIRED COMFORT LEVEL IN THE ROOM. 

CAUTION: DO NOT OBSTRUCT THE FRONT GRILLE OF THE HEATER SINCE THE PROPER OPERATION 

OF THE HEATER REQUIRES A FREE FLOW OF INTAKE AND EXHAUST AIR.

 

THE HEATER HAS A BUILT-IN MANUAL RESET THERMAL PROTECTOR WHICH PREVENTS OVERHEATING IF THE GRILLE 

OF THE HEATER IS ACCIDENTALLY BLOCKED.

 

TO  RESET  THE  THERMAL  PROTECTOR,  DISCONNECT  POWER  SUPPLY,  INSERT  SMALL  BLADE 

SCREW  DRIVER  OR  EQUIVALENT  THROUGH  GRILLE  INTO  VERTICAL  SLOT  LOCATED  ON  LOWER 
CENTER OF HEATER CHASSIS AND LIFT UP.

 

MAINTENANCE INSTRUCTIONS 

UNIT SHOULD BE CLEANED EVERY YEAR.  TO CLEAN: DISCONNECT MAIN SUPPLY, REMOVE FRONT SCREWS, UNPLUG UNIT 

AND SLIDE OUT.  AFTER CLEANING REPLACE UNIT AND ALL SCREWS TO MAINTAIN GOOD GROUND CONTINUITY. 

INSTALLATION INSTRUCTIONS 

1. SELECT AN AREA THAT IS NOT DIRECTLY UNDER SINK OR OTHER HEAVILY USED WORK AREA, AS THE AIR DISCHARGE 

TEMPERATURE MAY BE UNCOMFORTABLE.  FLOOR MATERIAL SHOULD BE CHECKED ADJACENT TO HEATER BEFORE 
INSTALLATION TO MAKE CERTAIN THAT IT WILL NOT DISCOLOR OR DISTORT.  (SOME TEND TO DISTORT AND DISCOLOR 

AT TEMPERATURES IN THE VICINITY OF 140

O

F.) 

2. 

CUT 22 3/8” BY 3 5/8” OPENING IN KICKSPACE AS SHOWN IN FIGURE 1. 

3. REMOVE SCREWS HOLDING HEATER COVER AND REMOVE COVER.  REMOVE DESIRED KNOCKOUT. 

4. RUN SERVICE CABLE (FROM THERMOSTAT, IF USED) TO KNOCKOUT AND ATTACH WITH AN APPROVED CONNECTOR, 

ATTACH GROUND WIRE UNDER GREEN GROUND SCREW.  HEATER IS FACTORY WIRED FOR 240/208 VOLT, 2000/ 
1500 WATTS.  (SEE OTHER SIDE FOR FIELD CONVERTED VOLTAGES AND WATTAGES) 

5.  WIRING: WIRE SERVICE CABLE TO RECEPTACLE WITH APPROVED CONNECTORS. 

6.  REPLACE  COVER  AND  SCREWS,  PUSH  UNIT  INTO  OPENING,  PUT  GRILLE  IN  PLACE  AND  ATTACH  UNIT  TO  CABINET 

USINGTWO SCREWS PROVIDED. 

BATHROOM VANITY

 

       

REV 5/14

 

   9823

 

  ECO 1-6949

 

Отзывы: