background image

This product is warranted to the purchaser against defects in material and workmanship for three years from the
date of purchase.

Covered by Warranty:

Repair parts and labor; or replacement of the product at company’s option. Normal trans-

portation charges to the purchaser are also covered.

Not Covered by Warranty:

Damages to the product which are the result of abuse, improper use or maintenance are

not covered. Any other expense, consequential damages, incidental damages, or incidental expenses including dam-
ages to property are not covered. Transportation expenses to the company are not covered.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limita-
tions or exclusions may not apply to you.

To Obtain Warranty Performance:

Include with the product: your name, address, phone number, written descrip-

tion of the problem and proof of purchase date. Carefully package and return to:

TPI, Inc.

TPI Canada

TPI, Europe Ltd..

9615 SW Allen Blvd.

342 Bronte Rd. S., Unit 6

Longley House, International Drive

Beaverton, OR  97005

Milton, Ontario  L9T 5B7

Southgate Crawley

USA

Canada

West Sussex  RH10 6AQ England

503-520-9197

905-693-8558

44(0) 1293 530196

www.testproductsintl.com

www.tpicanada.com

www.tpieurope.com

Implied Warranties: 

Any implied warranties including implied warranties of merchantability and fitness for a par-

ticular purpose, are limited in duration to three years from date of purchase. To the extent any provision of this war-
ranty is prohibited by federal or state law and cannot be preempted, it shall not be applicable. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

10

O. REPLACING BATTERIES

1. Turn the battery

compartment screw
counter clockwise
until it is just above
the compartment
door. Lift on the
screw to open the
compartment.

2. Replace the three

AAA batteries.

3. Re-install the battery cover and tighten the

screw by turning it clockwise.

N. WARRANTY

Содержание SP341

Страница 1: ...Visit www testproductsintl com Uses any K Type probe with sub mini connector Connects to smart phone and uses the TPI Smart Probe App Perform differential temperature meas urements with one instrument Up to 6 SP341 smart probes can connect to a single mobile device most devices Auto field calibrate to 1 F system accuracy in the range of 30 F to 120 F using field calibrate mode 3 Year Limited Warra...

Страница 2: ...w 2 E Taking a Measurement 3 F Additional App Features 4 G Drop Down Menu 5 H Entering Company and Customer Information 6 I Performing Differential Temperature Measurements 6 7 J Performing Field Calibration 8 K Maintenance 9 L Trouble Shooting 9 M Accessories 9 N Warranty 10 O Replacing Batteries 10 ...

Страница 3: ...robe It connects to your mobile device and uses the TPI Smart Probe App to display temperature readings Data can be exported to a CSV file as well B SAFETY CONSIDERATIONS 1 Never attach the SP341 to a hot surface 2 Always make sure the temperature probe used has the proper range for the application 3 Always use K Type thermocouples only 4 Do not expose the unit to damp environments for extended pe...

Страница 4: ...agnet Attach to metal surfaces for hands free operation Ensure surface is not hot 5 Serial number location Last three digits are the product identification number and marked in bold Use this num ber to distinguish between models when several SP341 s are connected to a phone or tablet 6 Screw to open battery com partment Turn the screw counter clockwise until it is just above the compartment door L...

Страница 5: ...onnected If the SP341 does not auto con nect tap refresh on the App Connect a probe to the SP341 and the temperature reading will be displayed If no probe is connected the dis play will read Open Refresh This also clears any data accumulated Displays the measured tem perature if a probe is con nected Displays Open if no probe is connected Note Open will also be dis played if a probe is bad break i...

Страница 6: ...Tap Data The measurement data is shown in a list with a date and time stamp Tapping the Refresh icon clears this data Tap the mail icon Test data will be exported in a CSV file via email 4 Exported data in the CSV file dis play with the date and time stamp If a company and customer name has been entered they will be exported too See page 5 for set ting up the customer and compa ny name Tap Graph E...

Страница 7: ...ions for the SP1000 Company Info Allows you to enter your information to show up on the CSV file report You can enter your company name address and email Customer Info Allows you to enter the information of the cus tomer the tests are being performed for You can enter the cus tomer name address and email You can also enter the building information in cases where the tests are being performed some ...

Страница 8: ...re off site from the customer The Smart Probe App allows you to enter your company information and the customer information who the test is being performed for This information will be exported in the CSV file see page 4 I PERFORMING DIFFERENTIAL TEMPERATURE MEASUREMENTS 1 Tap the Drop Down Menu icon to access addi tional features The Smart Probe App allows you to perform differential temperature ...

Страница 9: ...41 to probe to the next area 6 Tap Diff This is the T2 temperature T1 T2 and T1 T2 is displayed Date and time stamp information is dis played and can be exported via email 7 Repeat as neces sary 8 Use the Drop Down Menu to return to the Main Real Time Reading display as necessary 3 The T1 tempera ture will be dis played 4 The T2 tempera ture will be dis played 5 The T1 T2 differ ential temperature...

Страница 10: ...ater works well The temperature of an ice bath is approximately 32 F 0 F 1 Connect a tempera ture probe to the SP341 2 Tap the list icon to bring up the options menu 3 Select Zeroing Sensors to bring up the field calibra tion screen 6 Insert the temper ature probe into the ice water bath and allow the tem perature reading to stabilize at or near 32 F 0 C Note The dis played tempera ture must be wi...

Страница 11: ...er switch until unit turns on Defective POWER ON switch SP341 displays OPEN No probe connected Temperature probe is bad SP341 measures temperature Thermocouple probe wired backwards backwards Probe connected with reverse polarity M ACCESSORIES Included Accessories Part Number Description A341SP Soft pouch GK41M General purpose temperature probe Optional Accessories Part Number Description A925 Car...

Страница 12: ...purchase date Carefully package and return to TPI Inc TPI Canada TPI Europe Ltd 9615 SW Allen Blvd 342 Bronte Rd S Unit 6 Longley House International Drive Beaverton OR 97005 Milton Ontario L9T 5B7 Southgate Crawley USA Canada West Sussex RH10 6AQ England 503 520 9197 905 693 8558 44 0 1293 530196 www testproductsintl com www tpicanada com www tpieurope com Implied Warranties Any implied warrantie...

Страница 13: ...NOTES ...

Страница 14: ...NOTES ...

Страница 15: ...NOTES ...

Страница 16: ...w testproductsintl com Test Products International Ltd 342 Bronte Road South Unit 6 Milton Ontario Canada L9T 5B7 Tel 905 693 8558 www tpicanada com Test Products International Europe Ltd Longley House International Drive Southgate Crawley West Sussex RH10 6AQ Tel 44 0 1293 530196 www tpieurope com ...