background image

FORM: 9480 ECO 1-7255 REV. 01/17

1 OF 4

3480/RCH SERIES

INSTALLATION

 INSTRUCTIONS

GENERAL INFORMATION

MOUNT HORIZONTAL POSITION ONLY.

DO NOT INSTALL ANY CLOSER THAN 12” TO NEAREST WALL

MAXIMUM MOUNTING HEIGHT 12 FEET.

CHECK TO SEE THAT SERVICE VOLTAGE IS THE SAME AS HEATER VOLTAGE.

ALL WIRING MUST CONFORM TO THE NATIONAL ELECTRIC CODE AND EXISTING LOCAL CODE REQUIREMENTS.

INSTALLATION INSTRUCTIONS:

1.  Detach heater unit from the ceiling mounting plate in the 

recessed can by disengaging the stabilizing arms on 

ceiling plate from the heater unit.  4 - 

#8 drive screws.

2.  For a dropped or suspended ceiling, anchor the recessed 

can using either threaded rod, or wire in an approved 

method that is sufficient to support the heater assembly 

such that the bottom edge of the recessed can just 

rest on the T-bar frame. For plaster or similar finished 

ceilings, the can should be installed so the flanges (of 

the can) are even with the interior finish or ceiling line.

3. 

For  plaster  or  other  similar  finish  ceilings  attach  the 

PT3480 accessory plaster frame to the recessed can 

using 8 - 

#8 x 3/4 drive screws

. (detail “AA”)

4.  Hang heater unit from two stabilizing arms on the ceiling 

mounting plate in the can. Be sure to engage the two 

arms with the hooked ends on the ceiling plate with the 

slots in the heater plate.

5.  Connect the heater leads with their corresponding 

supply leads in the outlet box (75

O

C wire must be used). 

The outlet box is permanently attached to the top of 

the can. After this is complete, install the ceiling plate 

access hole cover with 2 - 

#8 drive screws

 which have 

been provided.

6.  Swing the heater unit up to the ceiling mounting plate 

and secure with 4 - 

#8 drive screws

 that have been 

provided. Do this by placing one screw in each  of the 

four stabilizing arms on the ceiling plate.

7. 

Install heater exterior grille by attaching it directly to the 

heater unit. Rotate the exterior grille so that the  two 

1/4” dia. holes in the exterior grille align with the manual 

reset limit control located on the bottom of the venturi 

of the heater assembly, also make alignments so that 

the venturi of the heater assembly  is on the outside the 

venturi of the      exterior grille. Secure to the four bracket 

arms on the heater case with 4 - 

10/32 x 3/4 button 

head machine screws

 provided.

WARNING:

 To avoid the risk of fire, shock or personal injury; make sure that the power source is disconnected before 

attempting to install, service, clean or disassemble the heater or any of its components. If the power disconnect is out of the 

line of sight, lock in in the open position and tag it to prevent the application of power. 

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

NOTE: If plaster frame is required for installation 

order it as an option.

ATTENTION: Read carefully 

before attempting to install 

or operate the heater. 

HANG HEATER UNIT FRO

M

TWO STABILIZING ARMS ON TH

E

CEILING MOUNTING PLATE IN THE CA

N

RECESSED HARD SURFACE

INSTALLATION

RECESSED T-BAR

INSTALLATION

RECESSED

DETAILS

EACH

CORNER

HEATER

BOX

T-BAR

BY OTHERS

HEATER

BOX

PT3480

1

4

2

7