Unmanaged/Easy Smart Rackmountable Switch

Installation

Extremely high voltage currents can be produced instantly when lightning occurs and the air in the 

electric discharge path can be instantly heated up to 20,000°C. As this instant current is strong 

enough to damage electronic devices, more effective lightning protection measures should be 

taken.

 

Ensure that the rack and the device are well earthed.

 

Make sure the power socket has a good contact with the ground.

 

Keep a reasonable cabling system and avoid induced lightning.

 

Use the signal SPD (Surge Protective Device) when wiring outdoor.

Note: 

For detailed lightning protection measures, refer to the Lightning Protection Guide from the 

Related Documents of our website: 

https://www.tp-link.com/en/configuration-guides/lightning_protection_guide/?configurationId=2962

Installation Site

When installing the device on a rack or a flat workbench, attach much importance to the following 

items:

 

The rack or workbench is flat, stable, and sturdy enough to support the weight of 5.5 kg at least.

 

The rack or workbench has a good ventilation system. The equipment room is well ventilated.

 

The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.

2.3  Installation Tools

 

Phillips screwdriver

 

ESD-preventive wrist wrap

 

Cables

Note: 

These tools are not included with our product. If needed, you can purchase them separately.

2.4  Product Installation

 

Desktop Installation

To install the device on the desktop, follow the steps:
1. Set the device on a flat surface which is strong enough to support the entire weight of the device 

with all fittings.

2. Remove the adhesive backing papers from the rubber feet.
3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at 

each corner of the device.

Содержание TL-SG1008PE

Страница 1: ...Installation Guide Unmanaged Easy Smart Rackmountable Switch Business Networking Solution...

Страница 2: ......

Страница 3: ...inistrator Conventions Some models featured in this guide may be unavailable in your country or region For local sales information visit https www tp link com The figures in Chapter 2 and Chapter 3 ar...

Страница 4: ...age Contents 9 2 2 Safety Precautions 9 2 3 Installation Tools 11 2 4 Product Installation 11 Chapter 3 Connection 13 3 1 Ethernet Port 13 3 2 SFP Port 13 3 3 Verify Installation 13 3 4 Power On 14 3...

Страница 5: ...d devices PDs complying with IEEE 802 3af and IEEE 802 3at Note PSE is a device switch or hub for instance that will provide power in a PoE setup PoE is a technology that describes a system to transmi...

Страница 6: ...e following figure Figure 1 4 Front Panel of TL SF1016DS 10 100Mbps RJ45 Port LEDs The front panel of TL SF1024D is shown as the following figure Figure 1 5 Front Panel of TL SF1024D 10 100Mbps RJ45 P...

Страница 7: ...e front panel of TL SG1024 is shown as the following figure Figure 1 8 Front Panel of TL SG1024 10 100 1000Mbps RJ45 Port LEDs The front panel of TL SG1048 is shown as the following figure Figure 1 9...

Страница 8: ...nt panel of TL SG1016D is shown as the following figure Figure 1 12 Front Panel of TL SG1016D 10 100 1000Mbps RJ45 Port LEDs The front panel of TL SG1024D is shown as the following figure Figure 1 13...

Страница 9: ...l of TL SG1008PE is shown as the following figure Figure 1 16 Front Panel of TL SG1008PE 10 100 1000Mbps RJ45 Port LEDs The front panel of TL SG1016PE is shown as the following figure Figure 1 17 Fron...

Страница 10: ...ng data Off No device is linked to the corresponding port Note Only for TL SG1048 and ports 1 to 16 of TL SG1218MPE The port 17 and port 18 of TL SG1218MPE which only support 1000M SFP module connecti...

Страница 11: ...lasts for more than 2 minutes Off Total power supply is less than 185 W Note Only for TL SG1218MPE FAN Green The fan works properly Yellow The fan doesn t work properly Note Only for TL SG1016PE and...

Страница 12: ...switch already comes with lightning protection mechanism You can also ground the switch through the PE Protecting Earth cable of AC cord or with Ground Cable For detailed information refer to the Ligh...

Страница 13: ...y injury caused by improper use you should observe the following rules Safety Precautions Keep the power off during the installation Wear an ESD preventive wrist strap and make sure that the wrist str...

Страница 14: ...nts Some measures have been taken for the device to prevent static electricity but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board To avo...

Страница 15: ...e configurationId 2962 Installation Site When installing the device on a rack or a flat workbench attach much importance to the following items The rack or workbench is flat stable and sturdy enough t...

Страница 16: ...f the device with supplied screws as illustrated in the following figure Figure 2 2 Bracket Installation Rack mounting Bracket Screw 3 After the brackets are attached to the device use suitable screws...

Страница 17: ...SFP port to an SFP module Figure 3 2 Inserting the SFP Module SFP Slot SFP Module Note TL SG1218MPE features 2 individual SFP ports which support 1000M SFP module connection only 3 3 Verify Installati...

Страница 18: ...ollows 1 The PWR Power LED indicator will light up 2 The LED indicators of all the ports will flash momentarily and then turn off again after the initialization 3 6 Accessing the Switch Note Only for...

Страница 19: ...min as both user name and password Now you can configure the switch using the Web based GUI For further information refer to the User Guide on the resource CD You can find the latest version of this g...

Страница 20: ...net of the switch 5 If you still cannot access the configuration page please reset the switch to its factory defaults Then the IP address of your PC should be set as 192 168 0 x x is any number from 2...

Страница 21: ...F1024 TL SF1024D TL SF1048 1000BASE SX 62 5 m MMF Minimum range 2 m 275 m or 50 m MMF Minimum range 2 m 550 m for TL SG1218MPE 1000BASE LX 62 5 m 50 m MMF Minimum range 2 m 550 m or 10 m SMF Minimum r...

Страница 22: ...Temperature 0 C to 40 C 32 to 104 F 0 C to 50 C 32 to 122 F for TL SG1218MPE Storage Temperature 40 C to 70 C 40 to 158 F Operating Humidity 10 to 90 RH Non condensing Storage Humidity 5 to 90 RH Non...

Страница 23: ...65 EU The original EU declaration of conformity may be found at https www tp link com en ce Safety Information Keep the device away from water fire humidity or hot environments Do not attempt to disas...

Страница 24: ...2019 TP Link 7106508362 REV13 1 0 For technical support the user guide and more information please visit https www tp link com support or simply scan the QR code...

Отзывы: