156
Example
Add a description Port _5 to port 1/0/5:
T1600G-52TS(config)#
interface gigabitEthernet
1/0/5
T1600G-52TS(config-if)# description
Port_5
19.4
shutdown
Description
The
shutdown
command is used to disable an Ethernet port. To enable this
port again, please use
no shutdown
command.
Syntax
shutdown
no shutdown
Command Mode
Interface Configuration Mode (interface gigabitEthernet / interface range
gigabitEthernet / interface port-channel / interface range port-channel)
Privilege Requirement
Only Admin, Operator and Power User level users have access to these
commands.
Example
Disable port 1/0/3:
T1600G-52TS(config)#
interface gigabitEthernet
1/0/3
T1600G-52TS(config-if)# shutdown
19.5
flow-control
Description
The
flow-control
command is used to enable the flow-control function for a
port. To disable the flow-control function for this corresponding port, please
use
no flow-control
command. With the flow-control function enabled, the
Ingress Rate and Egress Rate can be synchronized to avoid packet loss in the
network.
Syntax
flow-control
no flow-control
Содержание T1600-28TS
Страница 1: ...CLI Reference Guide T1600G Series Switches REV2 0 0 1910011957...
Страница 37: ...21 Example Clear the commands you have entered in the current mode T1600G 52TS config history clear...
Страница 57: ...41 T1600G 52TS config show voice vlan switchport gigabitEthernet 1 0 2...
Страница 64: ...48 Example Display the LACP system priority T1600G 52TS config show lacp sys id...
Страница 340: ...324 Example Display the summary information of IPv6 route entries T1600G 52TS config show ipv6 route summary...
Страница 365: ...349 Example Display the configuration of DHCP Relay T1600G 52TS config show ip dhcp relay...