JetStream L2/L2+ Managed Switch

17

Appendix A  Troubleshooting

Appendix A  Troubleshooting

Q1. 

What could I do if I forgot the username and password of the switch?

1.  Connect the console port of the PC to the console port of the switch and open a terminal 

emulation program. 

2.  Power off and restart the switch. Perform the action indicated by the terminal emulation program 

to reach the bootUtil menu. The action differs from product to product. Possible actions are 

listed below:

•  Press any key to stop autoboot.
•  Press CTRL-B to reach the bootUtil menu.

3.  The bootUtil menu will be shown. Enter the number 6 to select the “Password recovery” option 

and enter Y to delete all the users and passwords. The default login username and password are 

both 

admin

. The other configurations in the switch will not be changed.

4.  For models without the password recover feature, select the "Reset" option to restore all the 

configurations to factory defaults. The default login username and password are both 

admin

.

Q2. 

Why does the PWR/Power LED work abnormally?

The PWR/Power LED should be lit up when the power system works normally. If the PWR/Power 

LED worked abnormally, take the following steps:

1.  Make sure that the power cable is connected properly, and the power contact is normal.
2.  Make sure the voltage of the power supply meets the requirement of the input voltage of the 

switch.

Q3. 

What should I do if I cannot access the web management page?

Try the following:

1.  Check every port LED on the switch and make sure the Ethernet cable is connected properly.
2.  Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
3.  Power off the switch and, after a while, power it on again.
4.  Make sure the IP address of your PC is set within the subnet of the switch.
5.  If you still cannot access the configuration page, reset the switch to its factory defaults. Then 

the IP address of your PC should be set as 192.168.0.x ("x" is any number from 2 to 254) and 

subnet mask as 255.255.255.0.

Q4. 

Why is the terminal emulation program not displaying correctly?

Try the following:

1.  Make sure the power supply is normal and the console cable is properly connected.
2.  Check if the console cable is the right type.
3.  Ensure the parameters of the terminal emulation program are correct: configure Bits per second 

as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None.

Содержание JetStream TL-SG3210XHP-M2

Страница 1: ...Business Networking Solution Installation Guide JetStream L2 L2 Managed Switch...

Страница 2: ......

Страница 3: ...uide may be unavailable in your country or region For local sales information visit https www tp link com The figures in Chapter 2 Chapter 3 and Chapter 4 are for demonstration purposes only Your swit...

Страница 4: ...stallation Tools 08 2 4 Product Installation 08 Chapter 3 Connection 10 3 1 Ethernet Port 10 3 2 SFP SFP Slot 10 3 3 Console Port 10 3 4 Verify Installation 11 3 5 Power On 11 3 6 Initialization 12 Ch...

Страница 5: ...can fully meet the need of the users demanding higher networking performance TL SG3210XHP M2 TL SG3428MP TL SG3428XMP is also a Power Sourcing Equipment PSE All the RJ45 ports on the switch support P...

Страница 6: ...supply is abnormal Flashing Power supply is abnormal SYS Flashing The switch works properly On or Off The switch works improperly PoE Max On The remaining PoE power is 7 W Flashing The remaining PoE...

Страница 7: ...works improperly 10 100 1000M Green On Running at 1000 Mbps but no activity Green Flashing Running at 1000 Mbps and transmitting or receiving data Yellow On Running at 10 100 Mbps but no activity Yell...

Страница 8: ...transmitting or receiving data Off No device is linked to the corresponding port Note For TL SG3428MP SFP Green On Running at 10 Gbps but no activity Green Flashing Running at 10 Gbps and transmitting...

Страница 9: ...ice from being stolen Grounding Terminal The switch already comes with lightning protection mechanism You can also ground the switch through the PE Protecting Earth cable of AC cord or with Ground Cab...

Страница 10: ...ules Safety Precautions Keep the power off during the installation Wear an ESD preventive wrist strap and make sure that the wrist strap has a good skin contact and is well grounded Use only the power...

Страница 11: ...e electronic elements on the internal circuit board To avoid the effect of static electricity on the operation of the switch attach much importance to the following items Dust the device regularly and...

Страница 12: ...ice on a rack or a flat workbench attach much importance to the following items The rack or workbench is flat stable and sturdy enough to support the weight of 5 5 kg at least The rack or workbench ha...

Страница 13: ...ews as illustrated in the following figure Figure 2 2 Bracket Installation Rack mounting Bracket Screw 3 After the brackets are attached to the device use suitable screws not provided to secure the br...

Страница 14: ...able 3 2 SFP SFP Slot The following figure demonstrates the connection of SFP SFP slot to an SFP SFP module Figure 3 2 Inserting the SFP SFP Module SFP SFP Slot SFP SFP Module 3 3 Console Port CLI Com...

Страница 15: ...r off when plugging the console cable into the console RJ45 port Do not connect the console port with other ports by RJ45 cable 3 4 Verify Installation After completing the installation verify the fol...

Страница 16: ...Power On Self Test A series of tests run automatically to ensure the device functions properly During this time its LED indicators will respond in the following order 1 The PWR LED indicator lights o...

Страница 17: ...one Mode Switch PC Using the GUI 1 To access the management page of the switch make sure the switch and computer are in the same subnet Open a browser and type the switch s IP address in the address f...

Страница 18: ...ect your network and devices 4 3 Controller Mode Controller Mode applies to the large scale network with mass devices All devices can be centrally configured and monitored via Omada Software Controlle...

Страница 19: ...ou have no spare PC to keep running Omada Software Controller in the network It needs to be purchased additionally For more details refer to the Installation Guide of Omada Hardware Controller Omada C...

Страница 20: ...appear in the list once bound with your TP Link ID Click Launch and follow the step by step instructions to complete the Quick Setup After the wizard is finished log in via the created username and p...

Страница 21: ...em works normally If the PWR Power LED worked abnormally take the following steps 1 Make sure that the power cable is connected properly and the power contact is normal 2 Make sure the voltage of the...

Страница 22: ...category 5 5e or above cable maximum 100 m EIA TIA 568 100 STP maximum 100 m 2 5GBase T UTP category 5 5e or above cable maximum 100 m EIA TIA 568 100 STP maximum 100 m For TL SG3210XHP M2 10GBASE SR...

Страница 23: ...onformity may be found at https www tp link com en ce Safety Information Keep the device away from water fire humidity or hot environments Do not attempt to disassemble repair or modify the device If...

Страница 24: ...ineers please visit https community tp link com to join TP Link Community For technical support the user guide and other information please visit https www tp link com support or simply scan the QR co...

Отзывы: