Toyotomi Laser 301 Скачать руководство пользователя страница 1

LASER CLEAN HEATING SYSTEM/VENTED HEATER

INSTALLATION AND OPERATION INSTRUCTIONS

LASER CLEAN VENTED

MODEL

Laser 301 / Laser 302

(Type A)

IMPORTANT
READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. CHECK LOCAL CODES AND ORDINANCES FOR PERMITTED USE.

CONTENTS

SECTION A:
 Specifications
  Safety Features
SECTION B:
  Safety Tips for Operation
SECTION C:
  Fuel Guide
SECTION D:
  Operating Controls and Part Names
SECTION E:
 Operation
    Before Ignition
   Operation
    Turning Heater Off
SECTION F:
  Routine Maintenance

················································ 2

 ·············································· 3

································ 4

···················································· 5

················· 6

··········································· 9

················································· 10

···································· 14

···································· 15

············································· 17

········································· 18

······················ 19

························· 19

········································ 21

·························· 24

··············· 25

······················· 31

························································ 32

········································ 33

SECTION G:
 Troubleshooting
SECTION H:
  Long Term Storage
SECTION I:
 Installation
    Tools Needed for Installation
    Standard Installation Parts
    Accessary Parts
    Safety Tips for Installation
    Installation of Heater and Flue Pipe
    Permanent Wiring Installation
SECTION J:
 Fueling
SECTION K:
  Customer's Record

Содержание Laser 301

Страница 1: ...atures SECTION B Safety Tips for Operation SECTION C Fuel Guide SECTION D Operating Controls and Part Names SECTION E Operation Before Ignition Operation Turning Heater Off SECTION F Routine Maintenance 2 3 4 5 6 9 10 14 15 17 18 19 19 21 24 25 31 32 33 SECTION G Troubleshooting SECTION H Long Term Storage SECTION I Installation Tools Needed for Installation Standard Installation Parts Accessary P...

Страница 2: ... D3699 Low Sulfur No 1 Fuel ASTM D396 S500 Ultra Low Sulfur Diesel Fuel ULSD or Ultra Low Sulfur Heating Oil ULSHO ASTM D975 S15 17 3 8 21 3 4 15 1 8 440 555 385 mm 31 lbs 14 kg Empty 2 3 4 3 7 0 7 5 cm diameter 10 ft 3 m 3 bends or less 120 Volts AC 60 Hz Preheat 240W Burning 23W 600 square feet 0 F 720 square feet 20 F 2 400GHz to 2 4835GHz 20dBm IEEE 802 11n g b 1 2 3 Heat and vaporized water a...

Страница 3: ...very System If power fails during heater operation heater will automatically reignite and maintain the normal selected temperature when power resumes Fully Vented System Flue pipe system uses outside air for combustion and vents all combustion products to the outdoors 1 2 3 4 5 SAFETY FEATURES Your Laser 301 Laser 302 is equipped with the following safety features Please familiarize yourself with ...

Страница 4: ...lfur Diesel ULSD or Ultra Low Sulfur Heating Oil ULSHO NEVER USE GASOLINE Use of gasoline can lead to uncontrollable flames resulting in destructive fire 1 Due to high surface temperatures keep children furniture and clothing away from heater See Page 25 2 To prevent abnormal operation and prolong heater life be sure to perform routine maintenance See Pages 15 3 Never store or transport kerosene i...

Страница 5: ... of a highly volatile flammable fuel such as gasoline can produce uncontrollable flames creating a severe fire hazard Note The fluidity of Ultra Low Sulfur Diesel and Ultra Low Sulfur Heating Oil becomes worse at temperatures of 21 F 6 C and below and can gel This condition may cause ignition failure To prevent congealing it is recommended to use an additive with the fuel Check with a fuel supply ...

Страница 6: ...ing heater familiarize yourself with the following operating controls and names SECTION D OPERATING CONTROLS AND PART NAMES 5 POWER SAVER CHILD LOCK button 2 AUTO button 6 CLEAR button 15 Day of the week indicator 4 Set TEMP TIMER CLOCK DAY 7 Temperature select F C 3 TIMER button 10 TIMER indicator 9 AUTO indicator 18 AM PM indicator 17 WIFi LED 16 ON OFF TIMER indicator 13 BURNING MODE indicator ...

Страница 7: ...old the button to turn on or off the CHILD LOCK mode When reset the program for weekly timer the CLEAR button is used F C toggle switch Lit Heater is in operation Flashing Pre heating and pre purging Lit Weekly timer operation is in use Lit Weekly timer setting mode Lit Operating weekly timer set mode Lit Heater operating in CHILD LOCK mode Lit Heater operating at high medium or low combustion Lit...

Страница 8: ...8550 20475551 20475552 20470275 20470678 20470679 20471101 20471195 20471199 20471499 Front panel assembly L301 Front panel assembly L302 Top plate L301 Top plate L302 Operation panel L301 Operation panel L302 Rear guard right L301 Rear guard right L302 Rear guard left L301 Rear guard left L302 Rear guard top L301 Rear guard top L302 Circulation air filter Cabinet assembly L301 Cabinet assembly L3...

Страница 9: ...tlet On Display pre set Two Dashes will be showing Note Do not connect to an outlet shared with other appliances 4 Set Clock Important Clock on the heater must always be set to current time and day Note HOUR or MIN button will change the time every one 1 unit Holding the button continuously will cause the time to change rapidly Note In the event of a power failure more than approx 30 min all clock...

Страница 10: ...t time and a day of the week after setting the time and a day of the week the set mode of the current time will terminate and the operation will start If a day of the week is set the time is fixed If a day of the week is not set the contents of the setting are deleted OPERATION MANUAL OPERATION Operation of the heater is under the direct control of the user Heat output will however be automaticall...

Страница 11: ...ff As room temperature drops the heater will automatically re start to maintain the desired temperature POWER SAVER OPERATION The Power Saver mode reduces the frequency of ignition actions to save electric consumption Press the POWER SAVER button ON while in operation to start the operation of the POWER SAVER POWER SAVER sign will be shown on the display When the room temperature exceeds the selec...

Страница 12: ...SUN P2 SUN P3 SUN P4 MON P1 MON P2 SAT P4 NOTE When the HOUR button is pressed while at the bottom of programming which is P1 on Sunday SUN an alarm will sound twice and the program number cannot be changed If you press the MIN button while on P4 on Saturday SAT which is the top of the programming the alarm will sound twice and the program number cannot be changed 3 Press the SET button to confirm...

Страница 13: ...ss the SET button an alarm will sound four times and then the time that can be set will be displayed Also the same time cannot be set in the example above so you cannot have 7 00 AM for P1 and 7 00 AM for P2 on Sunday Temperature Settings 1 Press the MIN or HOUR button to select the desired temperature in that program The temperature flashes during setup 2 Press the SET button to confirm the desir...

Страница 14: ...econds when ON OFF button is ON 2 P1 P2 or P3 will be displayed on the display P1 Low mode P2 Medium mode P3 High mode Then select desired combustion mode by pressing MIN or HOUR button MIN button changes combustion mode to higher HOUR button changes combustion mode to lower 3 To clear press the MIN button and HOUR button at the same time for more than 3 seconds until normal temperature display re...

Страница 15: ...net rear side Once a week slide the filter up to remove and it should be vacuumed clean 3 Check for Fuel Leaks REGULARLY Make it a habit to check for any sign of fuel leakage along the fuel line and at all joints Fuel leaks may lead to risk of fire 4 Check Flue Pipe Area ONCE A MONTH Check the flue pipe joint to make sure connection is firm Use a vacuum cleaner to remove any dust or pet hair CAUTI...

Страница 16: ...necessary parts and replacing gaskets as needed Please ask your authorized Toyotomi dealer for details and scheduling When using Ultra Low Sulfur Diesel ULSD or Ultra Low Sulfur Heating Oil the heater should be serviced at least every two years because the distillation of ULSHO is heavier than 1 K Kerosene and No 1 Fuel Oil When using 1 K Kerosene or Low Sulfur No 1 Fuel Oil your heater can be ser...

Страница 17: ... 2 E 6 E 8 E 12 E 13 E 13 E 22 CAUSE Power failure unstable frequency Primary flame Flame sensor is malfunction and or dirty Fuel line malfunction Out of fuel no flame Flue pipe blockage or leak Blower motor malfunction High limit switch activated Burner thermistor failure Flue pipe blockage or leak Ignition failure three times SOLUTION Check power source Consult your dealer for cleaning and in sp...

Страница 18: ...loth 4 To store heater in another location a Disconnect heater b Close the main tank valve c Remove all fuel from the fuel sump and clean the fuel strainer d Disconnect fuel line and flue pipe from the heater Note Fuel remaining in the fuel line may flow out when fuel line is disconnected Have a container ready to catch drainage e Remove any soot accumulated in the flue pipe using a brush and or v...

Страница 19: ...3 4 to 3 diameter Making hole in wall for flue pipe Pipe Holder 1 PART 20474963 Wall Brackets 2 sets PART 20479562 Pipe Stopper 1 PART 20479864 The following standard installation parts are enclosed with heater For alternate installation methods you may need to purchase additional accessories which are available from your TOYOTOMI dealer See Accessory Parts page 26 SECTION I INSTALLATION ...

Страница 20: ...RT 20479584 L Shaped Hose 2 PART 20474975 Hose Band 2 PART 20474977 Spacer 1 PART 20478967 Screw M 3 PART 20474272 3 3 10 5 8 8 1 4 3 1 2 15 3 4 Inlet Hose 1 PART 20470261 Flue Pipe 1 PART 20479891 Exhaust Air Cap 1 PART 20479845 Intake Air Cap 1 PART 20474949 Screw 4G 3 PART 20474985 ...

Страница 21: ...t Use only genuine TOYOTOMI parts for your heater Use of unauthorized generic or other brand parts can severely reduce performance and safety and will void factory warranty Accessory Extension pipe kit L Extension pipe kit M Extension pipe kit S L Shaped exhaust joint Fuel lifter pump Model OPT 101 Pressure reducing valve Part No 20479898 20479897 20479896 20479861 20477600 10005099 Application Ex...

Страница 22: ...pe Holder Pipe Support Hardware L Shaped Exhaust Joint 1 1 1 2 2 3 sets 1 NOTE Use L shaped Exhaust Joint if necessary INSTALLATION WITH EXTENSION PIPE KIT L Adjustable Exhaust Pipe Insulation cloth cover Exhaust Extension Pipe long Pipe holder Intake Hose Pipe Support Hardware 20479861 20474963 20474950 20479853 20479872 20474951 20474955 Pipe Support Hardware Pipe Holder 2 pcs Pipe Holder Suppor...

Страница 23: ... PART 20479896 No Name of Part Q ty 1 2 3 4 5 6 Adjustable Exhaust Pipe Max 19 11 16 Min 12 5 8 Intake Pipe 20 inch Insulating cloth cover 40 inch Pipe Holder Pipe Support Hardware L Shaped Exhaust Joint 1 1 1 2 1 sets 1 Figure 3 20479861 20474963 20474950 20479853 20474951 20474955 Pipe Support Hardware Pipe Holder 2 pcs Pipe Holder Support 1 pc Screw 1 pc Wood Screw 2 pcs Nut 1 pc 6 4 5 3 3 8 3 ...

Страница 24: ...w collected leaves or strong drafts 5 Do not install the flue pipe down from the heater 6 Total length of extension pipe between heater and flue pipe must be no greater than 10 ft and no more than 3 bends NOTE When using extension pipes always cover the exhaust pipe with the insulating cloth cover 7 B Vent shall not be used in the vent system For all prescribed heater installations the flue pipe m...

Страница 25: ... to 3 000 ft above sea level For use at altitudes higher than 3 000 FT and up to 6 000 FT adjustments to the heater must be made Consult with your dealer MINIMUM CLEARANCE TO COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION 1 Select heater location Allow clearances as indicated below between heater and all other materials See Fig 1 Note These clearance are necessary to allow properly circulation and to...

Страница 26: ...sired position See Fig 4 NOTE Heater should be installed on a sturdy floor that is level and flat 5 Cut the hole for the flue pipe from inside the room Use a 2 3 4 to 3 diameter hole saw attached to an electric drill See Fig 5 The opening on the inside wall should be slightly higher than the outside opening approximately 1 4 so that the flue pipe will slope slightly downward approximately 2 degree...

Страница 27: ...the outer flue pipe through the hole Secure the outer flue pipe to the wall by turning it clockwise This locks the two halves together See fig 9 IMPORTANT Make sure the arrow on the outer flue pipe flange is pointing up Make sure to secure the outer flue pipe well A part shown in Fig 9 Check inside flue pipe for insulation and remore if any Fig 7 Fig 9 Inner flue pipe Wood screws Arrow Inside Outs...

Страница 28: ... with the heater Make sure the caps fit tightly onto the opening See Fig 10 NOTE If the inlet hose is not smoothly inserted into the L shaped hose apply water or soap suds to the inlet hose Do not use grease on air intake 7 Move the heater into position Remove the filter and the two 2 screws holding the upper rear cover Connect the bent joint to the exhaust outlet opening and attach the L shaped h...

Страница 29: ...oint to the standard flue pipe with the pipe holder If the extension pipe is used also attach the pipe holder to the connection of the bent joint and the extension pipe Secure the bent joint or the extension pipe to the exhaust outlet opening by sliding the pipe stopper into the exhaust opening bracket See Fig 12 Fig 12 ...

Страница 30: ...e on the back of the sensor and expose the adhesives Place the sensor on the desired location on the wall and press down b Wood Screw Screw down the wood screw provided with the heater into the desired location on the wall Hook the back of the room temperature sensor 10 After installation is completed secure heater to the wall with the wall brackets provided with the heater Make sure the heater is...

Страница 31: ...ly cord Step 5 Insert the power supply cable from the rear panel and connect ground wire to the power supply cord bracket and power wires to the terminals Step 6 Replace the front panel and secure the two 2 screws NOTE Emergency power supply and use of 12V DC batteries with an inverter Consult your dealer before attempting to use a battery inverter system to provide power for your Laser heater The...

Страница 32: ...ed to use an in line small mesh size filter with water block e g 10 micro filter Shut off valves should also be installed on the fuel line and connected the tank as illustrated on page 38 NOTE An additional shut off valve installed next to the heater will minimize fuel to be drained should heater have to be disconnected If the valve is on interior side a fusible link type is recommended 1 Be sure ...

Страница 33: ...0 0 6 12 18 0 0 6 12 18 0 0 6 12 18 0 0 6 12 18 0 0 6 12 18 0 0 6 12 18 0 WEEKLY TIMER PROGRAM MANAGEMENT TABLE TIME SET temp F F F F F F F TIME SET temp F F F F F F F TIME SET temp F F F F F F F TIME SET temp F F F F F F F Day SUN MON TUE WED THU FRI SAT P01 P02 P03 P04 SECTION K CUSTOMER S RECORD ...

Страница 34: ...ct please visit our website at www toyotomiusa com productRegistration php or scan the QR code on your smart device Make a note of your heater s serial and lot number located on the side of the cabinet Your heater s serial and lot number SERIAL NO ...

Страница 35: ......

Страница 36: ...OTOMI with this LIMITED WARRANTY and a copy of your bill of sale or credit card charge receipt or other documents evidencing the date of the Product s delivery if service is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYOTOMI U S A INC 604 Federal Road Brookfield CT 06804 203 775 1909 THE FOREGOING EXPRESSES ALL OF TOYOTOMI S OBLIGATIONS AND LIABILITIES WITH RESPECT ...