1.3 Wiring (for looms other than towel weaving machine)
45
1.3.5
Group Inverter
[ 1 ] Determination of installing location
To minimize the voltage drop, select a location to minimize the distance between the inverter and
loom. (See page 40 for the capacity of the cable between the inverter and loom.)
[ 2 ] Major specifications, dimensions and weight of inverter
*1
Inverters without a transformer are equipped with an AC reactor.
Inverter model
7P5L
011L
018L
022L
Major
specifications
Output current, A
33
46
76
92
Rating, kVA
11
16
26
32
Dimensions and
weight
Without
transformer
*1
Width (W mm)
500
500
600
600
Depth (D mm)
400
400
500
500
Height (H mm)
1000
1200
1300
1300
Weight (kg)
95
105
125
160
With
transformer
Width (W mm)
500
500
600
600
Depth (D mm)
400
400
500
500
Height (H mm)
1000
1200
1300
1300
Weight (kg)
120
150
170
220
4-ø12
W
RUN/STOP
RESET
PE
3øT
kVA
MCCB
50
50
50
50
D
H
50
17.5
17.5
D-65
D
30
30
W-60
Overall circuit
diagram
(affixed on back
side of door)
Direct
connection
Terminal
block
Ventilation port
Right side surface (3-ø34)
Left side surface
(4-ø34)
(each with rubber bush)