A00401
ON
3 (+)
DI--96
--
DIAGNOSTICS
ENGINE (2RZ--FE, 3RZ--FE)
When using hand--held tester
1 Connect the hand--held tester, and read value of air flow rate.
PREPARATION:
(a) Connect the hand -- held tester to the DLC3.
(b)
Turn ignition switch ON and push the hand--held tester main switch ON.
(c)
Start the engine
CHECK:
Read air flow rate hand--held tester.
RESULT:
Type I
Type II
Air flow rate (gm/sec.)
0.0 gm/sec.
271.0 gm/sec. or more
Type I
2 Check voltage of air flow meter power source.
PREPARATION:
(a)
Disconnect the air flow meter connector.
(b)
Turn ignition switch ON.
CHECK:
Measure voltage between terminal 3 of air flow meter connector
and body ground.
OK:
Voltage: 9
∼
14 V
NG
Check for open in harness and connector be-
tween EFI main relay (Marking: EFI) and air flow
meter
OK
CLICK HERE TO VIEW CHAPTER INDEX