Maintenance
TOX_Manual_Powerpackage_line-Q_en
61
10.4
Refilling oil and venting drive
1
8
9
2
11
12
10
8
2
4
12
3
9
10
5
6
11
1
Vent screw
2
Vent screw
3
Vent screw
4
Vent screw
5
Vent screw
6
Vent screw
7
Vent screw
8
High pressure measuring connection
9
Oil filling nipple
10
Oil level indicator
11
Venting plate
12
Oil anti-overfill safety device
13
Vent screw
Fig. 12 Refilling oil and venting drive
Material required:
Oil, filtered < 5 µm, load rating > 30 N/mm
2
(in accordance with
DIN 51524-2 HLP32)
If different special oils are used, see sticker.
Oil pump ZP 20