About this product
20
TOX_Manual_Process-monitoring-unit_CEP400T_en
Changes in a process, e.g. clinching process, results in deviations in the
press force. If the measured force exceeds or drops below the fixed limit
values, the process is stopped by the monitoring system. To ensure that
the process stops at "natural" deviations of the press force, the limit values
must be chosen correctly and not to narrow.
The function of monitoring equipment depends mainly on the setting of the
evaluation parameter.
3.3.4
Test of the final position of the closed tool
Clinching
The process monitoring system measures and evaluates the maximum
force reached.
To make a statement about a clinching process from the set minimum and
maximum limits, it must be ensured that the clinching tools were fully
closed (e.g. with a precision limit button).
If the measured force is then within the force window, it can be assumed
that the 'X' control dimension is in the required range.
The value for control dimension 'X' (residual bottom thickness) is specified
in the rest report and can be measured on the piece part with a measuring
sensor.
The limits of force must be adjusted to the minimum and maximum values
of the control dimnesion 'X' specified in the test report.
Punch
Die
Control dimension 'X'
(resulting bottom thickness)
Содержание CEP400T
Страница 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Страница 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 111: ...Repairs TOX_Manual_Process monitoring unit_CEP400T_en 111 11 Repairs 11 1 Repair work No repair work is necessary ...
Страница 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 115: ...Appendices TOX_Manual_Process monitoring unit_CEP400T_en 115 13 Appendices 13 1 Declaration of conformity ...
Страница 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 117: ......
Страница 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Страница 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...