100000363-50
12
TC42_NG05D_151117-16
For complete valve installation instructions, refer to the
instruction book included in the SIT conversion kit.
10. Open the air shutter by following the steps in the “Burner Flame Adjustment” on page 13.
11. Complete the gas valve conversion from natural gas to propane gas according to the instructions included
in the SIT propane gas conversion kit.
12. Once conversion is complete, fill out and place gas conversion label (Figure 27) to inside of control box
where it will not be affected by the heat of the firebox.
Pilot
adjustment
band
Figure 25: Pilot band in natural gas position.
Hole in sliding band
indicates propane
gas configuration
Figure 26: Pilot band in propane gas position.
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
10.0 in/wc / 10.0 po/c.e.
(2.49 kPa)
(2.49 mm)
Max.: 61,000 (17.9)
Min.: 48,000 (14.1)
190914 6-TC42D 5052.5206D
Date: ______________________
By / Par: ___________________
Kit # TC42D.LPKTB/EB/EC for use with model:
Pour utilise avec du modèle:
This appliance was converted
to PROPANE GAS with this
kit on this date by the or-
ganization which accepts the
responsibility that this conver-
sion has been properly made.
/ Cet appariel etair converter
au gaz LP par l’emploi de la
trousse de conversion par une
organization qui accepte la
responsibilité pour une instal-
lation en bon état.
TC42D
Series D
Figure 27: Propane conversion label.