Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 2001 12/01
LITERATURE NUMBER P103-4SI
PRINTED IN U.S.A.
CATALOG NUMBER 570-470
IF YOU NEED HELP call toll free: 1-800-565-5326
CONTENTS
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . 1
PACKAGE USAGE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COMPONENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Frames with Outer Screens
. . . . . . . . . . . . . . . . . . . . . . 2
Collecting Pads
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Charging Bar
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
High Voltage Power Supply Box
. . . . . . . . . . . . . . . . . . 2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3
Location
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electronic Air Cleaner Installation
. . . . . . . . . . . . . . . . 3
OPERATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Collecting Pad Replacement
. . . . . . . . . . . . . . . . . . . . . 3
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Im-
proper installation may damage media air cleaner.
Recognize safety information. This is the safety alert
symbol
. When the safety alert symbol is present on equip-
ment or in the instruction manual, be alert to the potential for
personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform the basic maintenance
functions of replacing collecting pads. All other operations
should be performed by trained service personnel. When work-
ing on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes. Wear safety glasses and work
gloves.
PACKAGE USAGE
GENERAL
The electronic air cleaner is designed to remove atmospher-
ic and household dust, pollen, mold spores, bacteria, fungi,
insecticide dust, animal dander, coal dust, mites, cooking
smoke and grease, tobacco smoke, and other particles down to
sub-micron levels.
The electronic air cleaner is installed in the furnace filter
rack where a filter would normally be placed. It is designed to
be installed in a 1-in. filter track. Many sizes are available to fit
in different size air ducts.
Airborne pollutants are carried through the return air ducts
of the heating/cooling system to the electronic air cleaner. The
collecting pads of the electronic air cleaner utilize electronic
polarization and ionization to create high filtration efficiencies.
The particles are captured by the collecting pads. The 1-in.
design protects HVAC equipment and their energy efficiencies
due to the electronic air cleaner’s low static pressure.
Regular maintenance (replacement or cleaning of collecting
pads) is required by the home owner.
IMPORTANT: Read entire instructions before
installing the electronic air cleaner.
Before beginning any installation or modification, be cer-
tain that the main line electrical disconnect switch is in the
OFF position. Electric shock could result. Tag disconnect
switch with suitable warning labels.
PART NUMBER
SIZE (in.)
P130-1224C
12 x 24
P130-1424C
14 x 24
P130-1425C
14 x 25
P130-1430C
14 x 30
P130-1520C
15 x 20
P130-1620C
16 x 20
P130-1624C
16 x 24
P130-1625C
16 x 25
P130-1820C
18 x 20
P130-2020C
20 x 20
P130-2024C
20 x 24
P130-2025C
20 x 25
P130-2424C
24 x 24
P130-2425C
24 x 25
P130-2430C
24 x 30
INSTALLATION,
OPERATION, AND
MAINTENANCE
INSTRUCTIONS
1300 Series
Electronic Air Cleaner
Содержание 1300 Series
Страница 7: ...7 ...