TEI
Operation Manual
Contents subject to change without notice
Version 1.1
5/2020
Страница 1: ...TEI Operation Manual Contents subject to change without notice Version 1 1 5 2020...
Страница 2: ...Mode Counting Mode 6 Percent Weighing Mode Percent Weighing Mode Percent Weighing Mode Percent Weighing Mode 7 Set Set Set Setup Mode up Mode up Mode up Mode 8 Calibration Mode Calibration Mode Calibr...
Страница 3: ...nterface Interface Interface RS232 COM1 and USB COM2 Feet Feet Feet Feet 4 x fixed bolt design adjustable height Max Max Max Max Overload Overload Overload Overload 120 of capacity P P P Plllla a a at...
Страница 4: ...data entry position by one Menu selection mode Goes to next item of current sub menu UNIT UNIT UNIT UNIT DATA DATA DATA DATA Weighing mode 3 seconds Changes weighing unit of measure Counting or Perce...
Страница 5: ...on the display 3 Put the material or object to be weighed in the container The net weight will be displayed 4 To exit tare mode remove all weight from the scale The display will show a negative weight...
Страница 6: ...ched within the stabilization time default of 9 seconds the scale will display STB ER STB ER STB ER STB ER Press the TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to HOLD HOLD HOLD HOLD again or...
Страница 7: ...ck Weighing Data Compare Data Compare Data Compare Data Compare Mode Mode Mode Mode The check weighing or data compare function allows the user to input a pre set range and the display will indicate w...
Страница 8: ...e If the input piece weight is less than 0 5d where d the scale s readability see specifications the indicator will display PWt Er PWt Er PWt Er PWt Er and will automatically return to counting mode b...
Страница 9: ...he HOLD HOLD HOLD HOLD SETUP SETUP SETUP SETUP key for 4 seconds to input the decimal point Press the TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to confirm and return to percent weighing mode...
Страница 10: ...USER USER USER Setup mode If you enter the wrong mode press the HOLD HOLD HOLD HOLD SETUP SETUP SETUP SETUP key to return to the main menu or press ZERO ON OFF ZERO ON OFF ZERO ON OFF ZERO ON OFF to...
Страница 11: ...O COUNT YES Yes No enable disable output counts Prompt is QUANTITY NO NO PCWT YES Yes No enable disable output piece weight Prompt is PIECE WT NO NO BMI YES Yes No enable disable output height and BMI...
Страница 12: ...2 output mode 1 NONE No communication 2 CONT Continuous output 3 PRINT Output when PRINT FUNC PRINT FUNC PRINT FUNC PRINT FUNC key is pressed scale must be stable 4 CMD Output when a request command i...
Страница 13: ...NO COUNT YES Yes No enable disable output counts Prompt is QUANTITY NO NO PCWT YES Yes No enable disable output piece weight Prompt is PIECE WT NO NO BMI YES Yes No enable disable output height and BM...
Страница 14: ...ative value relative to the last zeroed value TOGGLE 4 TOGGLE Press HOLD key to hold the data as long as weight is over NLD RNG and stable Press HOLD key again to exit AVERAG 5 AVERAG Average HOLD If...
Страница 15: ...cuted 4 COM 1 2 command from COM1 or COM2 will be executed COM 1 COM 1 COM 2 COM 1 2 A OFF T 0 255 Auto off time 0 no auto power off 1 255 auto off after 1 255 minutes of no operation or weight change...
Страница 16: ...Use the arrow keys adjust the input value to the standard calibration weight you will use Note Note Note Note do not use less than 10 of the scale s rated capacity do not use less than 10 of the scale...
Страница 17: ...cale s capacity END Y YES End calibration YES go to CAL END NO go to next point calibration NO CAL P2 Linear calibration point 2 does second weight point calibration Standard weight should be more tha...
Страница 18: ...TARE PRESET TARE PRESET key Use the arrow keys to select the geographic adjustment code for your location 00 70 using Table 1 Press TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to confirm Note...
Страница 19: ...setup 4 Press the UNIT DATA UNIT DATA UNIT DATA UNIT DATA key for 4 seconds to enter date modification mode Use the arrow keys to modify the date If no entry is made within 5 seconds it will automatic...
Страница 20: ...llowed the first digit for positive Decimal point 1byte Measure unit 1 5bytes lb kg lb oz pcs units are always lower case and left aligned Current status 4bytes If over capacity the scale will return...
Страница 21: ...re The details of Prompt refer to the content in User Setup User Setup User Setup User Setup submenu In hold mode if the A D conversion speed is set to high 80Hz and USER USER USER USER COM1 2 COM1 2...
Страница 22: ...E PRESET TARE PRESET TARE PRESET to enter Either rd1 rd1 rd1 rd1 or td1 td1 td1 td1 or rd2 rd2 rd2 rd2 or td2 td2 td2 td2 will be displayed Note Note Note Note A cable must connect the indicator to a...
Страница 23: ...sure Weight reading below minimum load limit Install platform on scale Perform zero calibration EEP E2 EEP E2 EEP E2 EEP E2 USER parameters are not correctly set Re set settings in USER mode CAL Er CA...
Страница 24: ...Character Definitions Definitions Definitions Definitions Packing Packing Packing Packing Content Content Content Contents s s s Indicator w tilting bracket Scale platform base AC120V DC6V 500mA UL ad...
Страница 25: ...23 Totalcomp Inc 99 Reagent Lane Fair Lawn NJ 07410 Tel 800 631 0347 Fax 888 797 2287 www Totalcomp com...