Startup and operation
RES-407
Page 23
curve, in other words it must not jump abruptly,
fluctuate or deviate temporarily in the wrong
direction. This kind of behavior would indicate that
the U
R
measuring wires have been laid incorrectly.
If an error message is displayed, please proceed as
described in section 10.13 "Error messages" on
page 32.
11.Burn in the heatsealing band (
ª
"Burning in the heatsealing band" on page 21) and
repeat the AUTOCAL function.
9.4.2
Restart after replacing the
heatsealing band
To replace the heatsealing band, proceed as described
in section 9.3.2 "Burning in the heatsealing band" on
page 21 .
Always use a heatsealing band with the
correct alloy, dimensions and copper-plating
in order to avoid malfunctions and overheating.
Continue with section 9.4.1, steps 4 to 11.
The controller is now
ready
!