Startup and operation
RES-407
Page 19
9
Startup and operation
9.1
View of the controller
9.2
Controller configuration
The controller must be switched off in order
to configure the coding switches and the
plug-in jumpers.
9.2.1
Configuration of the DIP switches
for secondary voltage and current
Automatic configuration (AUTORANGE)
(as of April 2005)
The secondary voltage and current ranges are
automatically configured by the automatic calibration
function (AUTOCAL). The voltage is configured in the
range from 0.4VAC to 120VAC and the current in the
range from 30A to 500A. If the voltage and/or the
current is outside the permissible range, a detailed
error message appears on the controller (
ª
see
section 10.13 "Error messages" on page 32).
Configuration with coding switches
(up to March 2005)
Set the DIP switches for matching the secondary
voltage U
2
and the secondary current I
2
to the correct
position for
your
application.
You can find the exact configuration of the
DIP switches in the ROPEX Application
Report calculated for your particular application.
Terminals
Wiring diagram
LEDs
Coding switches and
plug-in jumpers
Nameplate
!
!