Tosot 5,000 BTU-GPC05AK-A3NNA1C Скачать руководство пользователя страница 1

User Manual

Portable Air Conditioner

Before using your TOSOT Portable Air Conditioner

please read this user manual in its entirety. 

MO DEL NUMBERS

5,000 BTU-GPC05AK-A3NNA1C         6,000 BTU-GPC06AK-A3NNA1C

Содержание 5,000 BTU-GPC05AK-A3NNA1C

Страница 1: ...User Manual Portable Air Conditioner Before using your TOSOT Portable Air Conditioner please read this user manual in its entirety MODEL NUMBERS 5 000 BTU GPC05AK A3NNA1C 6 000 BTU GPC06AK A3NNA1C ...

Страница 2: ...ol in certain areas Standing the unit upright for 3 4 hours allows the refrigerant to move freely within the coils 3 Some parts with sharp edges may cause injury so gloves are highly recommended for unpacking and installing 4 Run the unit continuously for 24 hours after letting the unit stand upright for 3 4 hours This allows the unit to work out any kinks that may have resulted during shipping fr...

Страница 3: ... Control Combination Buttons Replacing the Batteries Installation Tools Required Parts List Installing Your AC Installing the Exhaust Hose Removing Collected Water Installing the Power Cord Hooks Cleaning and Maintenance Troubleshooting Malfunction Codes Warranty Customer Support 01 01 02 05 06 06 08 10 11 11 11 12 13 18 19 21 22 24 25 26 ...

Страница 4: ...ss under the direct supervision of a person responsible for their safety Please keep plastic bags and sheets out of the reach of children as they might be mistakenly used for play Packaging materials can become airtight chambers and may pose a risk of suffocation if not disposed of properly When installing or moving the appliance be careful not to pinch crush or damage the power cord Never attempt...

Страница 5: ... by pulling on the power cord Never use the appliance if the outlet is damaged or loose This product should be plugged directly into a power outlet Power outlets should be properly rated protected and sized in order to avoid electrical overload Do not cut or remove the third ground prong from the power cord Always unplug the unit from the outlet before cleaning or maintenance operations Your air c...

Страница 6: ...upply cord will have two buttons on the plug head If you press the TEST button you should notice a clicking noise as the RESET button pops out 3 Press the RESET button again and you will notice a clicking noise as the button engages 4 The power supply cord is now supplying electricity to the unit Do not use the LCDI plug to turn the unit on or off Always make sure the RESET button is pushed in for...

Страница 7: ... noise and vibration Avoid direct sunlight exposure 61cm 24 30cm 12 30cm 12 Note The following locations or conditions may cause malfunction or damage to your air conditioner Avoid running the air conditioner under the following conditions Near strong heat sources vapors flammable or explosive gas or volatile objects spread in the air Around any high frequency devices such as welding machines or m...

Страница 8: ...only for reference Please refer to the actual product for the appearance 6 1 8 7 6 9 10 5 1 2 3 4 Remote Control Control Panel Vertical Airflow Louver Horizontal Airflow Louver Caster Wheels Air Intake Joint Exhaust Hose Rear Clip Power Cord Power Cord Hooks ...

Страница 9: ...an operate the air conditioner by using the control panel or remote The air conditioner will emit a beep after pressing each button on the control panel The dual 8 nixie tube on the control panel will display the set temperature when incooling mode but won t display anything in other modes The dual 8 nixie tube won t display anything while the air conditioner is powered off ON OFF Button Timer But...

Страница 10: ... sleep operation mode Sleep mode is not available for Fan mode and Dry mode When in sleep mode the AC temperature will automatically increase by 2 F for the first hour and 4 F for the second hour and then will keep running with this temperature ON OFF Button Press to power the air conditioner ON or OFF Timer Button When the unit is running press this button to schedule when the unit will power off...

Страница 11: ...the remote control is 25 feet with no obstacles or interference from other devices such as wireless phones or fluorescent lamps The air conditioner will emit a beep sound if the signal from the remote has been received successfully ON OFF button MODE button button FAN button X FAN button SLEEP button TIMER button On Off Signal Sending X Fan Sleep Mode Child Lock Mode Speed Setting Time Setting Tem...

Страница 12: ...by 1 F Holding the button for 2 seconds will cause the temperature to change rapidly Release the button once your desired temperature is reached After pressing the Timer button each press of the button will increase decrease the time by 0 5 hours Holding the button for 2 seconds will cause the timer to change rapidly Release the button once your desired time setting has been reached Fan Button Pre...

Страница 13: ...s displays Sleep Button Press this button to enter the sleep operation mode While in sleep mode you can only use the Cool modes When in sleep mode the AC temperature will automatically increase by 2 F for first hour and 4 F for second hour and then will keep running with this temperature Timer Button Press this button to activate the timer button Use the buttons to adjust the length of the timer b...

Страница 14: ...r and slide out following the engraved arrow 2 Replace with two new AAA 1 5V batteries not included of the same make and model Make sure the polarities are aligned correctly 3 Reinstall the battery cover box reinstall remove battery cover of battery box Phillips head screwdriver Tape measure Scissors Saw Pencil ...

Страница 15: ... for window installation FAN ON OFF MODE SLEEP TIMER LOCK X FAN SLEEP X FAN SPEED T ON T OFF H AU OPER TO FAN DR COO Y L Window panel Extension panel Exhaust cover Adjustment panel Fixed Clip x 2pcs Bracket Foam Seal A non adhesive Foam Seal B adhesive type Rain Guard x 2pcs Accessory kit for installing the drain hose Remote Control Power Cord Hook x2pcs Others ...

Страница 16: ...attach it to your horizontal or vertical sliding window Foam seal B adhesive type Foam seal B adhesive type 2 Attach the insect guard to the back side of the window panel Push in to ensure that it fits securely If you do not want to install the rain guard skip to Step 4 below 3 Optional Install the rain guard over the insect guard to prevent rainwater from leaking into the exhaust hose a Insert th...

Страница 17: ... window b Insert the insect guard firmly to ensure that the four projections fit into the holes of the window panel Make sure that Side A is on the top Double hung sash window Sliding sash window Projection A Window panel Window panel Projection A 4 Slide the Exhaust Cover into the grooves of the Window Panel Insert the first groove ...

Страница 18: ...ur exact window size You may not need to use all three panels To begin please refer to the guide below If your window is less than 28 inches long you only need the window panel You may need to saw off part of the window panel if your window is smaller than the window panel length If your window is 28 to 46 inches long you will need the window and adjustment panel You will not need the extension pa...

Страница 19: ...d clip until there is no gap between the two panels d Screw the mounting plate into the fixed clip to secure the panels together once it is at the length of your window mounting plate fixed clip e If needed follow the above steps to connect the other side of the adjustment panel to the extension panel The total length of the panels will reach 62 inches If your window is longer than 62 inches you wi...

Страница 20: ...urely against the Window panel 7 Stuff Foam Seal A non adhesive between the glass and the window to prevent air and insects from getting into the room 8 Optional Attach a bracket to the window frame with a screw to prevent any gaps from opening up Foam Seal A Bracket Bracket ...

Страница 21: ...ool air If you don t connect the exhaust hose your unit will exhaust this hot air into the room you are trying to cool That won t work very well 1 Twist the Joint and Rear Clip clockwise onto the exhaust hose Clockwise Rear clip Exhaust hose Clockwise Joint 2 Insert the Joint into the groove on the back of the unit and extend the exhaust hose groove clasp the side with TOP is upwards 3 Attach the ...

Страница 22: ...he display panel will show an H8 malfunction code to remind you to drain the water For manual drainage you will need to 1 Move the unit to a suitable place for discharging water Please keep the unit horizontal so water does not spill 2 Remove the rubber plug from the drainage port and the collected water will drain Tips In order to improve the cooling efficiency of your air conditioner the exhaust...

Страница 23: ...ll need to insert the hose to the port first before operation and secure it with a pipe clip Then attach it to the drainage pipe clip at the back of the machine When draining remove the hose from the clip and water will flow from the pipe Continuous Drainage Water can be drained into a floor drain by attaching a drain hose included to the continuous drain port 1 Remove the continuous drain cap by ...

Страница 24: ...g the continuous drainage option make sure that the air conditioner is located on a flat level surface and that the drain hose is directed downwards and clear of any obstructions Placing the air conditioner on an uneven surface may result in the chassis filling with water until the H8 malfunction code is displayed If this occurs manually empty the water in the chassis then recheck the air conditio...

Страница 25: ... Locate the filter and remove it from the air conditioner You may need to move the filter around to loosen 2 Clean the filter After removing use the dust attachment of your vacuum to suck up any dirt or warm water mixed with a mild detergent A soft bristle brush may help remove some of the dirt if needed 3 Reinstall the filter After the filter has dried completely reinstall back into the air condi...

Страница 26: ...lled tightly and free of damage Post Season Maintenance Checklist Disconnect unit from the power outlet Clean air filter and exterior case Drain any accumulated water from the air conditioner Wrap the air conditioner in plastic to prevent the accumulation of dust Long Term Storage Checklist Disconnect unit from the power outlet Clean air filter and exterior case Wrap and or cover the unit to preve...

Страница 27: ...uring operation such as water flowing Abnormal sound during operation such as a rapid pop pop sound Issue Troubleshooting Solution What is 3 Minute Compressor Protection All TOSOT Air Conditioners have a 3 Minute Compressor Protection feature to help extend the lifespan of your unit You may notice this happening when the unit is not blowing cold air or you can t hear the sound of the compressor Be...

Страница 28: ... operation but the fan continues to operate Compressor stops operation but the fan continues to operate Compressor stops operation but the fan continues to operate Compressor stops operation but the fan continues to operate H8 F0 F1 F2 F4 H3 Malfunction Code on Unit Malfunction Name Symptoms If you notice or experience any of the following conditions please turn off the air conditioner disconnect ...

Страница 29: ...anufacturing and material defects Please visit https tosotdirect com warranty for more details 2 Additional 6 Month warranty extension You can get a 6 month warranty extension by registering your new product at www tosotdirect com extend Customer Support Questions We are here to help support tosotdirect com 1 702 514 1603 www tosotdirect com Share your experience tosotdirect ...

Страница 30: ...27 ...

Отзывы: