28
RE V. 2.1/12-13
e
nvironmental
features
Allowable Temperature: from 15 °C to 40 °C. Humidity: 10% to 90% (non-condensing).
5.3.2 e
leCtriCal
ConneCtion
Must be in place near the machine.
• Turn off the power to the outlet or junction box where you would like to connect the machine.
• Make sure the connection of the grounding is operative and functional.
• Verify that the power supply line is adapted to the power of the machine.
• Check the switch on the power line carrying power to the machine and that its power interruption is suitable for a hypothetical
situation of failure.
• Connect the power cord to a power characteristics suitable for the plug provided with the cable.
• For proper electrical connection the machine must be connected to the phase to neutral and the ground conductor.
• Turn the power to the electrical line carrying power to the machine.
5.3.3 t
est
Before operating, ordinary and continuing use of the machine, check the perfect functioning general, performing at least some test
application.
If you feel vibrations or noises particular during operation, stop the machine immediately and investigate the cause.
5.3.4 i
nstallation
Have you received a chest containing a bare chassis and support.
u
nPaCking
The support is presented as a single block with a drawer for the collection of refuse material and two guides. It is preferable to unpack the
media before the machine. Unpack the guides and place them on the stand.
C
ontent
• the machine
• A hex wrench. To mount (to be kept)
• A guard for the protection of the tool
• BHC two screws M 12 X 25
• Two spacers for the connecting rods
• a pedal
• Four carrying handles
Ch a P t ER 5: INsta L L at ION