– 112 –
INTERFACE MANUAL
STE 85457
Electrical rating
Electrical rating
Notes
Rated voltage 24 V DC
Rated current 100 mA (Max.)
Select the optimum external power supply
based on the system specifications (power
capacity) of the customer.
If a current exceeding the rated output flows,
the output elements can be damaged or the
board can be burned. Therefore, be sure to
always use within the rated current range.
Use of an external power supply can result in
a breakdown, and so never use an external
power supply.
8.3
Fabricating Extension I/O Signal Cable
Follow the points below when fabricating the extension I/O signal cables.
a. Either use the connectors supplied with the TR48DIOCN/TR48DIOC, or prepare
the same type of connectors for use. Equivalent products by other manufacturers
(D-sub connectors) can also be used.
Connector name
Connector model
Manufacturer
INPUT
XM3A-3721 (plug-type connector)
XM2S-3711 (connector cover)
OMRON
OUTPUT
XM3A-2521 (plug-type connector)
XM2S-2511 (connector cover)
b. Select the cables that are used based on the specifications below.
Core wires: 0.18 mm
2
to 0.32 mm
2
twisted wire
Cable outer diameter: Maximum 113 mm diameter (INPUT), 111 mm diameter
(OUTPUT)
Shielding: Uniform shielding
Cable length: 30 m max.
Use of cables that do not match the specifications can result in a meltdown due
to a short-circuit or core wire overheating and also presents a danger of robot
malfunction due to the intrusion of noise. Therefore, never use cables outside the
specifications range.